CESSNA®
MODEL 525B
MAINTENANCE MANUAL
Table 15. LH Gen Bus Bar (HZ041)
Circuit Breaker
Equipment
Number of Units
Equipment Load
(Amps DC)
Notes
LH
Generator(HZ079)
GCU Gen Sense -
LH
1
0.02
LH Generator
(HZ081)
GCU 28 V DC - LH
(BT003)
1
10.00
HZ075
LH Start Control
PCB (NZ101)
1
0.51
Bus Calculated Load
10.53
Table 16. RH Gen Bus (HZ011)
Circuit Breaker
Equipment
Number of Units
Equipment Load
(Amps DC)
Notes
HZ124
Power Relay - RH
(KZ007)
1
0.50
Bus Calculated Load
0.50
Table 17. RH Power Feed Bus (HZ014)
Circuit Breaker
Equipment
Number of Units
Equipment Load
(Amps DC)
Notes
Compressor Motor
(UT024)
1
85.00
Compressor
(HZ028)
Compressor
Hourmeter (ET001)
1
0.00
HZ025
#1 RH DC Power
1
HZ026
#2 RH DC Power
1
HZ027
#3 RH DC Power
1
HZ024
RH 225 Amp Limiter
(HZ024)
1
Bus Calculated Load
85.00
Table 18. RH #1 CB Power Bus (HZ036)
Circuit Breaker
Equipment
Number of Units
Equipment Load
(Amps DC)
Notes
HZ050
Limiter Fault -RH
1
HZ052
Bus Sense - RH
1
0.06
HZ066
ENG PT2/TT2
HTR-RH (UZ004)
1
4.00
24-55-01
Page 18
© TEXTRON AVIATION INC.
Feb 23/2022
ICA-525B-34-00004
Form 2261 Rev 1