CESSNA®
MODEL 525B
MAINTENANCE MANUAL
Table 21. Hot Battery Bus (HZ008) (continued)
Circuit Breaker
Equipment
Number of Units
Equipment Load
(Amps DC)
Notes
Battery Charge
(UT012)
1
5.00
HZ108
Emergency Power
Relay (KZ014)
1
0.10
HZ133
LH Start Relay
(KZ010)
1
0.50
HZ128
RH Start Relay
(KZ012)
1
0.50
Bus Calculated Load
6.80
Table 22. HZ009
Circuit Breaker
Equipment
Number of Units
Equipment Load
(Amps DC)
Notes
HZ111
Auxiliary Battery
Voltage
1
0.01
Bus Calculated Load
0.01
Table 23. Hot Battery CB Bus (HZ012)
Circuit Breaker
Equipment
Number of Units
Equipment Load
(Amps DC)
Notes
Emergency Locator
(HZ144)
ELT Remote Switch
(UT505)
1
0.10
HZ139
Battery Voltage
1
0.01
HZ146
BATT DISC RLY
(KT001)
1
0.35
HZ138
LH Start Control
PCB (NZ101)
1
0.51
HZ143
RH Start Control
PCB (NZ100)
1
0.51
WING Anti-Ice
System - LH
(HZ149)
LH Wing A/I PWR
Relay (KZ023)
1
0.10
Wing Anti-Ice
System - RH
(HZ148)
RH Wing A/I PWR
Relay (KZ024)
1
0.10
EMER Lights
(HZ150)
EMER Impact SW
Reset
1
0.00
24-55-01
Page 21
© TEXTRON AVIATION INC.
Feb 23/2022
ICA-525B-34-00004
Form 2261 Rev 1