Receptacle Display
CAUTION
: Charger enclosure may be hot during charging. Use hand protection if handling the charger while charging.
Extension cords must be 3-wire cord no longer than 30m(100’) at 10AWG or 7.5m(25’) at 16AWG per UL guidelines.
Only connect
ONE
QuiQ charger to a single 15A circuit or the circuit may become overloaded.
Delta-Q QuiQ Charger Manual
2
www.delta-q.com
Fault Indicator (
Red Light
)
Charger error. Refer to troubleshooting information below.
If solid: AC power is present.
If flashing: Low AC voltage. Check electrical source and cord length.
AC Indicator
Charge Indicator
(
Orange Light
)
If solid: Greater than 80% state of charge
Charge Completion Indicator (
Green Light
)
If solid: Charging is complete
Displays scale of output current
If only ammeter and AC
Indicator LEDs are lit:
Less than 80% state of
charge
If flashing: Output has
been reduced due to
high internal charger
temperature.
Ammeter
Troubleshooting Instructions
If a fault occurs, count the number of red flashes between pauses and refer to the table below.
LED
Indication
Solid
Charge complete
Long flash
Greater than 80% state of charge
Short flash
Less than 80% state of charge
Off
See charger for indications.
Flashes
Cause
Solution
Charger unable to apply wake-up
pulse
Refer cart to service department
Charge timeout
Possible BMS error - refer cart to service department
BMS fault
Refer cart to service department
Charger shutdown due to high
internal temperature.
Ensure sufficient cooling airflow. Reset the charger
by interrupting AC power for 15+ seconds.
Internal charger fault
Reset the charger by interrupting AC power for 15+
seconds. Return to service department if fault persists.
Note: This is a Class A product. In a domestic environment this product may cause radio interference, in which case the
user may be required to take adequate measures.
Charger 10-LED Display
(
Orange Light
)
If off: Less than 80% state of charge or pre-charge
Summary of Contents for Cushman HAULER 800X ELiTE 2019
Page 1: ...OWNER S GUIDE 678059 C RIVISED JANUARY 2019 ISSUED JULY 2018 HAULER 800X ELiTE...
Page 12: ...4 INTRODUCTION...
Page 20: ...12 SAFETY...
Page 34: ...26 OPERATION Always secure the cargo...
Page 50: ...42 MAINTENANCE LOG DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Page 51: ...MAINTENANCE LOG 43 DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Page 52: ...44 MAINTENANCE LOG DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Page 53: ...MAINTENANCE LOG 45 DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Page 54: ...46 MAINTENANCE LOG DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Page 55: ...APPENDIX A A 1 APPENDIX A BATTERY CHARGER USER S GUIDE...
Page 58: ...A 4 APPENDIX A...
Page 59: ...APPENDIX B A APPENDIX B DECLARATION OF CONFORMITY...
Page 60: ...B APPENDIX B...
Page 61: ...APPENDIX B C...
Page 62: ...D APPENDIX B...
Page 63: ...APPENDIX B E...
Page 64: ...F APPENDIX B...