Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
6
EK1240LT/X and EK1240CLT/X Crimping Tools
Operation
• Inspect tool and dies before use. Replace any
worn or damaged parts. A damaged or improp-
erly assembled tool can break and strike nearby
personnel.
• Carrying strap is for carrying only, not to be used to
hang or suspend tool.
Failure to observe these warnings could result in
severe injury or death.
Electric shock hazard:
This tool is not insulated. When using
this unit on or near energized electri-
cal lines, use proper personal protec-
tive equipment.
Failure to observe this warning could
result in severe injury or death.
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection could
result in serious eye injury from flying
debris or hydraulic oil.
Pinch points:
• Remove battery before changing
dies, adapters, or jaws.
• Keep hands away from the crimp-
ing tool head when crimping.
Failure to observe these warnings
could result in severe injury or death.
• Do not use this tool for continuous use. After 30 to
40 cycles, allow the tool to cool for 15 minutes.
• Do not secure this tool in a vise. This tool is
designed for hand-held operation.
• This tool may be used in damp or wet environments;
however, air-drying is recommended before use if
the tool becomes soaked. Damage may result when
the tool is operated prior to thorough drying when
electrical components are soaked.
• Use this tool for the manufacturer’s intended
purpose only.
Failure to observe these precautions may result in
injury or property damage.
Charging the Battery
Read the instructions supplied with the battery charger.
LED Work Light (white)
This LED automatically turns on when the trigger is
pulled. It remains on for 10 seconds after the trigger is
released.
LED Indicator (red)
This tool is equipped with a special circuit board incor-
porating several important features to inform the user
about the current status of the unit. The LED signals in
the following cases:
What happens
Signal
What it means
Constant light for 20 seconds
at end of cycle
Battery charge is below
17 V at beginning of cycle*
Tool will
not
start, and
constant light for 20 seconds
when trigger is released
Battery charge is below
16 V at beginning of cycle*
Tool will stop, and constant
light for 20 seconds after
trigger is released
Battery voltage drops
below 13 V during cycle*
Tool will stop, and flashing
light for 20 seconds when
trigger is released
Motor current exceeds
20 A during cycle
Circuit has become too hot
Flashing light for 20 seconds
at end of cycle
Send tool in for service
* Running the battery below 16 V can damage the battery.