Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
8
EK6ATLT and EK6ATLX Battery-powered Crimping Tools
Connector Selection
Tool Range:
Copper — 4 AWG to 500 kcmil (except as noted
∆
)
This tool is cUL and UL classified for use with the following connector brands:
CONNECTOR
TYPE
BARREL
TYPE ANDERSON BLACKBURN
®
BURNDY
ILSCO
PANDUIT
T&B
PENN-
UNION
NO. OF
CRIMPS*
Copper
Splices
Short
VHSS
CSP
YS-L
CT
SCSS/SCS
54506–54518
BCU
4 to 4/0 AWG:
1 crimp
250 to
500 kcmil:
2 crimps
Long
VHS
CU
YS
CTL
SCL/SCH
54806–54818
BBCU
Copper
Lugs
Short
VHCS
CTL-2/CTL
YA-2LN/YA-L/YA-2L
YA/YA-L-TC/YA-L-2TC
CSW
∆
CRA/CRB
LCAS/LCA
LCD
54106–54118
54206–54286
BLU
Long
VHCL
CTL-L/LCN
YA-2N
CLN, CLW
∆
CRA-L/CRB-L
CRA-2L/CRB-2L
LCB/LCC 54906BE–54919BE
54854BE–54876BE
BBLU
*Use the number of crimps listed in the last column instead of
the number provided with the connector.
∆
ILSCO Capacity: 4 AWG to 250 kcmil
95R7
LCD Screen
This tool has an LCD screen, which displays informa-
tion about the tool. Turn on the screen by inserting the
battery and jogging the tool. If there are any problems
with the tool, an error code appears.
Error Code Meaning
1
Overcurrent fuse
2
Overcurrent comparator
3
Overheated circuit board
4
Overheated battery
5
Battery empty; operation stops
6
Faulty crimp; complete cycle
7
Faulty crimp; incomplete cycle
8
Low battery
9
Battery empty; tool won’t run
10
Real-time clock battery low
11
Tool deactivated
12
Service necessary
13
Real-time clock not found
14
Bluetooth
®
unit not found
15
Mobile unit not found
16
Pressure sensor not found
17
Burst pressure exceeded
18
Battery temperature too low
If there is no error code, cycle through the various
displays using the left and right buttons on either side of
the screen. There are seven displays in total.
Display Information Shown
1
Bluetooth
®
status, battery charge, current
pressure, max. pressure
2
Firmware, available firmware update,
serial number
3
Current user. Press and hold both buttons to
change user, select with right button, and confirm
by jogging the tool.
4
GSM/CDMA signal strength
5
GPS signal status
6
Cycles until next service
7
Since manufacturing: operating hours, capacity,
number of cycles
Note: Tool data transmission starts with production of
the tool, independent of registration on i-connect, but
only for the T version of this tool.