Instruction
Manual
ESSG
page
24
___________________________________________________________________________
The electric-hydraulic cutting unit is equipped with a sophisticated circuit board indicating
the user when the next service is due. (Pls. read chapter 4.3 for more information) The unit
must then be returned to an authorised service center.
If the seals are damaged the warranty is invalidated.
5.5. Oil changing cycles
It is advisable to have the unit serviced by a specialist during regular intervals to safeguard
a technically proper state before use.
Table 2 Service schedule
What
When
who
____________________________________________________________
Cleaning
after
each
use
Service
personnel
Check
oil
level weekly
Service
personnel
Check high pressure hose
weekly
Specialist
Change hydraulic oil
every 2 years
manufacturer/ASC’s
The hydraulic oil has to be completely changed after two years. The oil change must be
done by the manufacturer. Changing the oil must be documented.
5.6. Reference as to which (spare-) parts can be exchanged by the customers
Within the determined use of the unit the customer is only allowed to change the blades
(Pos.-No. 12a&b).
Attention
Do not destroy the seals of the unit!
Do not attempt to repair the tool yourself, and do not remove any parts such as screws and
other components.
5.7. Storage and transport of the unit
To avoid damaging the unit during transport it should always be transported in a carrying
case. It must be paid attention that the insulating hose (Pos.-No. 9) is properly rolled up
avoiding an extreme bending radius.
6. Troubleshooting
The hydraulic safety cutting unit is basically trouble-free. Should nevertheless be trouble
with this unit return it to the manufacturer or contact the manufacturer for advice.
Below there is a list of possible errors and their remedy:
The cutting cycle can not be terminated properly.
=>
Inform the net provider, respectively the control office, immediately. In case it must be
assumed that the blades have already cut into the cable special caution is required.
Summary of Contents for Klauke ESSG120/2