background image

22

23

Positioning and mounting of the base station and the transmitter 

 

y

When placed outdoors, choose a shady and dry place for the transmitter. Direct 
sunlight may trigger incorrect measurement and continuous humidity damages 
the electronic components needlessly. 

 

y

Place the base station in any room of the house.  Make sure to avoid the 
vicinity of any source of interference such as computer screens, TV sets or solid 
metal objects.

 

y

Once the desired location is chosen, check whether the transmission from the 
transmitter to the base station is possible (transmission range of up to 100m  
in open areas). Within solid walls, especially ones with metal parts, the  
transmission range can be reduced considerably. 

 

y

If necessary, choose, another position for the outdoor transmitter  
and/or receiver.

 

y

If the transmission is successful, you can place or wall mount the base station 
and the outdoor transmitter with the suspension device. 

Additional outdoor transmitters (optional)

 

y

When having more than one external transmitter, select a different channel for 
each one with the 1/2/3 switch inside the transmitter’s battery compartment. 
Insert two new AA 1.5 V batteries, polarity as illustrated. Start the base station 
operation or the manual search for the outdoor transmitter.

 

y

Choose the respective channel by pressing the CHANNEL button. 

 

y

Press and hold the CHANNEL button for three seconds. The last registered 
transmitter (channel) will be cancelled and the manual search begins.

 

y

Press the TX button in the corresponding transmitter’s battery compartment.  
The transmission of the outdoor data will take place immediately.

 

y

The outdoor values and the channel number will be shown on the base station 
display. If you have installed more than one outdoor transmitter, press the 
CHANNEL button on the base station to change between the channels 1 to 3.     

 

y

You can also choose an alternating channel display. Press CHANNEL button.  
After the last registered channel (1 to 3) a circle symbol   will appear.  
To deactivate the function press the CHANNEL button again.

 

y

After a successful installation close the outdoor transmitter’s battery  
compartment carefully.

Battery replacement

 

y

As soon as the battery symbol 

 will appear on the outdoor values display 

of the base station or on the display of the outdoor transmitter, change the 
batteries of the outdoor transmitter. 

 

y

Change the batteries of the base station, when the battery symbol 

 appears 

on the indoor values display.

 

y

Please note: When the batteries are changed, the contact between the trans-
mitter and the receiver must be restored – so always insert new batteries into 
both devices or start the manual search for the transmitter.

Troubleshooting

Problem

Solution

No indication on the base 
station/transmitter

Ensure the batteries’ polarities are correct
Change the batteries

No transmitter reception
Display “- -” 
for channel 1/2/3

No transmitter installed
Check the outdoor transmitter’s batteries  
(do not use rechargeable batteries!)
Restart the transmitter and the base station 
according to the manual 
Start the outdoor transmitter manual search 
Choose another place for the outdoor transmit-
ter and/or the base station
Reduce the distance between the outdoor 
transmitter and the base station
Check if there is any source of interference.

No DCF reception

Press and hold the -/MIN button for three 
seconds and start the initialisation manually.
Wait for an attempt reception during the night
Choose another place for your device
Set the clock manually
Check if there is any source of interference.
Restart the instrument according to the manual  

Incorrect indication

Change the batteries

If your device fails to work despite these measures, contact the retailer where you 
purchased the product.

Summary of Contents for 35.1162.54

Page 1: ...XENA Bedienungsanleitung Instruction manual Mode d emploi Istruzioni per l uso Gebruiksaanwijzing Instrucciones de uso Kat Nr 35 1162 54...

Page 2: ...nstrucciones de uso Las instrucciones de uso se adjuntan al dispositivo o pueden descargarse de www tfa dostmann de en service downloads instruction manuals No emplee el dispositivo de modo distinto a...

Page 3: ...4 5 Fig 1 Fig 4 Fig 2 Fig 3 A F G A B C B C H D E J A B C D E F G H J K L M N T1 T2 T3 C rH 19 C 19 25 C 30 rH 60 rH 30 39 rH 40 60 rH 25 30 C 30 C T4 O P Q R S...

Page 4: ...legen der Batterien Verwenden Sie nie gleichzeitig alte und neue Batterien oder Batterien unterschiedlichen Typs Entfernen Sie die Batterien wenn Sie das Ger t l ngere Zeit nicht verwenden Beim Hantie...

Page 5: ...ichen blinkt y Halten Sie noch einmal die MIN Taste f r 3 Sekunden gedr ckt ist der Empfangsvorgang beendet Das DCF Empfangszeichen verschwindet y Es gibt drei verschiedene Empfangssymbole y blinkt Em...

Page 6: ...r MAX Taste zur Abfrage der H chstwerte MAX blinkt im Display Zur ckstellung der H chst und Tiefstwerte a Manuelle Zur ckstellung y Dr cken und halten Sie die SET Taste f r 3 Sekunden w hrend die maxi...

Page 7: ...ieb oder starten Sie die manuelle Sendersuche y W hlen Sie mit der CHANNEL Taste den gew nschten Kanal aus y Halten Sie die CHANNEL Taste f r drei Sekunden gedr ckt Der registrierte Sender Kanal wird...

Page 8: ...m nationalen oder lokalen Bestimmungen abzugeben Die Bezeichnungen f r enthaltene Schwermetalle sind Cd Cadmium Hg Quecksilber Pb Blei Dieses Ger t ist entsprechend der EU Richtlinie ber die Entsorgun...

Page 9: ...batteries together nor batteries of different types Remove the batteries if the device will not be used for an extended period of time Wear chemical resistant protective gloves and safety glasses whe...

Page 10: ...ate the DCF reception manually Press the MIN button for 3 seconds The DCF reception symbol will be flashing y Press and hold the MIN button again for 3 seconds to stop the reception process The DCF re...

Page 11: ...maximum values MAX flashes on the display Reset of maximum and minimum values a Manual reset y Press and hold the SET button for 3 seconds during the highest or lowest values are displayed The values...

Page 12: ...ss the CHANNEL button on the base station to change between the channels 1 to 3 y You can also choose an alternating channel display Press CHANNEL button After the last registered channel 1 to 3 a cir...

Page 13: ...al regulations in order to protect the environment The symbols for the contained heavy metals are Cd cadmium Hg mercury Pb lead This product is labelled in accordance with the EU Waste Electrical and...

Page 14: ...s avec des piles neuves ou des piles de types diff rents Retirez les piles si vous n utilisez pas votre appareil pendant une dur e prolon g e Pour manipuler des piles qui ont coul utilisez des gants d...

Page 15: ...dant 3 secondes le pro cessus de r ception est termin Le symbole de r ception DCF dispara t y Il y a trois symboles de r ception diff rents y Clignote r ception en cours y Allum en continu la r ceptio...

Page 16: ...tialisation des valeurs maximales et minimales a R initialisation manuelle y Appuyez sur la touche SET pendant 3 secondes lorsque les valeurs maximales ou minimales s affichent Les valeurs mesur es se...

Page 17: ...nt la recherche de l metteur y Appuyez sur la touche CHANNEL et s lectionnez l metteur correspondant y Maintenez la touche CHANNEL appuy e pendant trois secondes L metteur enregistr canal est effac et...

Page 18: ...e votre domicile conform ment la r glementation nationale et locale Les m taux lourds sont d sign s comme suit Cd cadmium Hg mercure Pb plomb Cet appareil est conforme aux normes de l UE relatives au...

Page 19: ...ate Non utilizzate mai contemporaneamente batterie usate e batterie nuove n batterie di tipi diversi Rimuovere le batterie se non si utilizza l apparecchio per un periodo prolungato Quando si maneggia...

Page 20: ...ere premuto di nuovo il tasto MIN per 3 secondi il processo di ricezione terminato Il simbolo della ricezione DCF scompare y Ci sono tre differenti simboli di ricezione y Simbolo lampeggiante Ricezion...

Page 21: ...ggio dei valori massimi e minimi a Resettaggio manuale y Tenendo premuto il tasto SET per 3 secondi durante la visualizzazione dei valori massimi e minimi I valori vengono cancellati e viene ripristin...

Page 22: ...te polarit Ponete in funzione la stazione base o avviate la sintonizzazione manuale y Selezionate con il tasto CHANNEL il corrispondente trasmettitore y Tenere premuto per tre secondi il tasto CHANNEL...

Page 23: ...isposizioni nazionali o locali ai fini di uno smaltimento ecologico Le sigle dei metalli pesanti contenuti sono Cd cadmio Hg mercurio Pb piombo Questo apparecchio etichettato in conformit alla Diretti...

Page 24: ...en Gebruik nooit tegelijkertijd oude en nieuwe batterijen of batterijen van een verschillend type Verwijder de batterijen als u het apparaat langere tijd niet gebruikt Draag chemisch bestendige handsc...

Page 25: ...t y Als u de MIN toets nogmaals 3 seconden lang ingedrukt houdt is het ont vangstproces gestopt Het DCF ontvangstsymbool verdwijnt dan y Er zijn drie verschillende ontvangstsymbolen y Knippert ontvang...

Page 26: ...toets om de maximumwaarden op te vragen Op het display knippert MAX Terugstelling van maximum en minimumwaarden a Handmatige terugstelling y Druk op de SET toets en houd deze 3 seconden ingedrukt wann...

Page 27: ...handmatig zenderzoeken y Kies met de CHANNEL toets de desbetreffende zender y Houdt de CHANNEL toets drie seconden ingedrukt De geregistreerde zender kanaal wordt gewist en het zenderzoeken begint y D...

Page 28: ...lingen te brengen om een milieuvriendelijk verwijderen te garanderen De benamingen van de zware metalen zijn Cd cadmium Hg kwik Pb lood Dit apparaat is gemarkeerd in overeenstemming met de EU richtlij...

Page 29: ...o pilas de diferente tipo Extraiga las pilas si no va a usar el dispositivo por un largo per odo de tiempo Utilice guantes protectores resistentes a productos qu micos y gafas protecto ras si manipul...

Page 30: ...y 5 00 de la ma ana y Tambi n puede activar la recepci n de la se al DCF manualmente Mantenga pulsada la tecla MIN durante 3 segundos El s mbolo de recepci n DCF parpadea y Mantenga pulsada la tecla...

Page 31: ...este procedimiento con la tecla MAX para consultar los valores m ximos MAX parpadea en la pantalla Reposici n de valores m ximos y m nimos a Reposici n manual y Mantenga pulsada la tecla SET durante...

Page 32: ...ueda manual del emisor y Con la tecla CHANNEL puede seleccionar el emisor deseado y Mantenga pulsada la tecla CHANNEL durante 3 segundos El emisor canal registrado se borrar y comenzar la b squeda del...

Page 33: ...os de recogida y reciclaje previstos para ello seg n el reglamento nacional o local Las denominaciones de los metales pesados que contienen son Cd cadmio Hg mercurio Pb plomo Este dispositivo est iden...

Page 34: ...Kat Nr 35 1162 54 TFA Dostmann GmbH Co KG Zum Ottersberg 12 97877 Wertheim Germany...