POSITIONING THE THERMO-HYGRO TRANSMITTER: 

 

 

The Thermo-hygro transmitter can be placed onto 
any flat surface or wall mount using the bracket 
which doubles as a stand or wall mount base. 

 

To wall mount:  

1. 

Secure the bracket onto a desired wall using 
the screws and plastic anchors. 

2. 

Clip the transmitter onto the bracket.   

 

 
 
Note:

  

Before permanently fixing the transmitter wall base, pace all units in the desired locations to 
check that the outdoor temperature and humidity readings are receivable. In event that the 
signal is not received, relocate the transmitters or move them slightly as this may help the signal 
reception. 

 

CARE AND MAINTENANCE:

 

 

Extreme temperatures, vibration and shock should be avoided as these may cause 
damage to the units and give inaccurate forecasts and readings. 

 

When cleaning the display and casings, use a soft damp cloth only. Do not use solvents or 
scouring agents as they may mark the LCD and casings. 

 

Do not submerge the units in water. 

 

Immediately remove all low powered batteries to avoid leakage and damage. Replace only 
with new batteries of the recommended type. 

 

Do make any repair attempts to the units. Return it to their original point of purchase for 
repair by a qualified engineer. Opening and tampering with the units may invalidate their 
guarantee. 

 

Do not expose the units to extreme and sudden temperature changes, this may lead to 
rapid changes in forecasts and readings and thereby reduce their accuracy. 

 
 

SPECIFICATIONS:

 

Temperature measuring range: 
Indoor 

:  -10ºC to +69.9ºC with 0.1ºC resolution 

 

+14°F to +157.8°F with 0.2°F resolution 

 

(

“OF.L”

 displayed if outside this range) 

Outdoor 

:  -29.9ºC to +69.9ºC with 0.1ºC resolution 

 

-21.8°F to +157.8°F with 0.2°F resolution 

 

(

“OF.L”

 displayed if outside this range) 

Relative humidity measuring range: 
Indoor 

:  1% to 99% with 1% resolution 

 

(

“- -”

 displayed if outside this range) 

Outdoor 

:  1% to 99% with 1% resolution 

 

(

“- -”

 displayed if outside this range) 

Indoor temperature checking interval  :   every 15 seconds 
Indoor humidity checking interval 

:  every 20 seconds 

Outdoor temperature reception 

:   every 5 minutes 

Outdoor humidity reception 

:  every 5 minutes 

Transmitter checking interval 

:  every 1 minute 

Air pressure checking interval 

:  every 15 seconds 

Transmission range 

:   up to 100 meters (open space) 

Power supply: 

 

 

 

Weather Station 

:   3 x AA, IEC LR6, 1.5V 

Thermo-hygro transmitter 

:  2 x AA, IEC LR6, 1.5V 

Battery life cycle 

:  approximately 12 months 

(Alkaline batteries recommended) 

 

 

Table stand/wall 
mount bracket

 

Summary of Contents for IQ-WS 35.1040

Page 1: ...ntelligent Weather Station together with the optimum benefit of all its features FEATURES The Intelligent Weather Station DCF 77 Radio controlled time with manual setting option DCF reception ON OFF u...

Page 2: ...after 3 minutes the batteries will need to be removed from both units and reset from step 1 4 The Weather Station can receive up to 3 remote Thermo hygro transmitters If you have purchased additional...

Page 3: ...ime base for the radio controlled time is a Cesium Atomic Clock operated by the Physikalisch Technische Bundesanstalt Braunschweig which has a time deviation of less than one second in one million yea...

Page 4: ...midity record Combine with the CH key to re detect a new transmitter in displayed channel Stop the alarm during the time alarm or weather alarm ringing Back light ON CH key Channel key Select channel...

Page 5: ...ather alarm ringing Back light on Reset all MIN MAX records ALM TIME key Enter the alarm time setting mode Stop the alarm during the time alarm or weather alarm ringing Back light on ALM Data key Ente...

Page 6: ...unit setting Air pressure unit setting Relative pressure value setting Language display setting Outdoor temperature in C or F Indoor general alarm icon Seconds display Indoor relative humidity in RH...

Page 7: ...firm with the SET key and enter the Manual Time setting MANUAL TIME SETTING In case the Weather Station cannot detect the DCF signal for example due to disturbances transmitting distance etc the time...

Page 8: ...the DCF time reception function is turned OFF manually the clock will not perform any reception of the DCF time as long as the DCF OFF function is activated The DCF reception icon will not be display...

Page 9: ...the manual setting anytime during the manual setting modes press the CH key anytime or wait for automatic timeout The mode will return to normal time display TIME ALARM SETTING The alarm time can be...

Page 10: ...y to set the alarm value 3 Press the SET key to confirm and enter the HIGH indoor temperature alarm setting IV If no LOW indoor temperature setting is needed please press the ALM DATA key to enter the...

Page 11: ...ly be set for channel 1 transmitter To set the HIGH outdoor temperature alarm default OFF I Buzzer ON OFF alarm sounding 1 Press the ALM STOP key to set buzzer ON OFF The icon will appear if the buzze...

Page 12: ...n the LOW outdoor humidity alarm setting there are optional sub settings Note The outdoor humidity alarm can only be set for channel 1 transmitter To set the LOW outdoor humidity alarm default OFF I B...

Page 13: ...will be shown in normal display when the weather alarm is set ON To exit the weather alarm setting mode anytime press the CH key or wait for automatic timeout The mode will return to normal time displ...

Page 14: ...m icon will flash when the outdoor temperature and humidity alarm occurs To switch off the general alarm icon press the ALM DATA key Additionally the trigged alarm value and time will then be displaye...

Page 15: ...ainy icon since the icons are already at their extremes The icons displayed forecasts the weather in terms of getting better or worse and not necessarily sunny or rainy as each icon indicates For exam...

Page 16: ...sections of the sections of the LCD show the relative air pressure and the air pressure history The reference relative air pressure hPa can be set between 960 to 1040hPa See Relative pressure value se...

Page 17: ...mperature the reception indicator the minimum or maximum reading A number in the bottom part will also be shown if more than one transmitter has been used TOGGLING BETWEEN MIN MAX INDOOR AND OUTDOOR R...

Page 18: ...learned again by entering the channel re learn mode To re learn ALL channels 1 Press and hold the CH key for 3 seconds outdoor reception signal will show next to channel display To re learn the CURRE...

Page 19: ...xx xx MinTemp xx x C Heute xx xx MinTemp xx x C Aujourdhui xx xx Snowfall Index 65 Schnee Index 65 Neige Index 65 Probability of snowfall Index 75 Index 75 Index 75 Fog Index 80 Nebel Index 80 Brouill...

Page 20: ...or window frames 3 Using other electrical products such as headphones or speakers operating on the same signal frequency 433MHz may prevent correct signal transmission and reception 3 Neighbours usin...

Page 21: ...pts to the units Return it to their original point of purchase for repair by a qualified engineer Opening and tampering with the units may invalidate their guarantee Do not expose the units to extreme...

Page 22: ...designed to be used in the home as indication of the future weather and is not 100 accurate Weather forecasts given by this product should be taken only as an indication and not as being totally accur...

Reviews: