6. Control Panel
Position
Descriptions
1
2
Indication lamp area of three operation
modes set by motor pump.
Button for setting operation modes of
the motor pump.
6.1.
Controls on Control Panel
6.2. Indication Lamp Area of Motor
Pump Setting
APUMP-HE series circulation motor pump has
settings which can be chosen with the button.
The motor pump settings are indicated with
different indication lamp areas.
three
three
10
Button Times Indication Lamp Area
0
1
2
AUTO (
)
Initial setting
MIN
MAX
Descriptions
Self-adaptive (AUTO)
Constant Speed Curve, Velocity Min
Constant
Curve, Velocity Max
Speed
6.3.
By pressing the button once at 2 seconds interval, the motor pump setting mode will
change to the next in sequence.
A cycle is constituted of every
presses on the button. For details, please refer
to Section 6.2.
Button for selecting motor pump settings
three
APUMP-HE