95
5-9 CDI UNIT
Use megga meter to check the following
items.
Check Item
Measuring Terminals
Standard Value (20
o
C)
Main Switch
Black/White - Body Ground Continuity , When Main Switch "OFF"
Exciting Coil
Black/Red - Body Ground
300 ~ 1000 Ohm
Pulser Coil
Blue/Yellow - Body Ground
40 ~ 300 Ohm
Primary Coil
Black/White - Green
0.1 ~ 1.0 Ohm
Secondary Coil
Green - Spark Plug Cap
7 ~ 12 k Ohm
A. Exciting Coil Inspection
Disassembly:
The exciting coil
connector.
Measure:
A. Use megga meter‘s positive
terminal to connect exciting coil’s
black/red terminal.
B. Connect the megga meter‘s
negative terminal with frame
ground and measure the
Note:
(1) The standard resistance is: 300~1000
Ohm (20
o
C).
(2) If the resistance is higher than
standard, then it is broken.
Please replace with new one.