DVOR 432
Fault Location
Operation and Maintenance
6-4
Ed. 01.04
6.1.3.5
Modulation Depth of Carrier too low (4)
Applicability:
VOR: 9960 Hz auxiliary carrier, identity and voice, not for 30 Hz AM composed of carrier and sideband.
DVOR: 30 Hz AM, identity and voice, not for the 9960 auxiliary carrier, which is composed of carrier and
sideband.
* 100 W version only
Step
Fault
A
B
C
4.1
One monitor
good, one
monitor bad
Search for the fault in the bad
monitor and continue with 8.1.
Condition: neither monitor may
have more than 110 % RF
level; otherwise, measuring erĆ
rors may occur.
4.2
Bothmonitors
show the same
fault.
Search for the fault in the
transmitter.
Condition: neither monitor may
have more than 110 % RF
level; otherwise, measuring erĆ
rors may occur.
TX1/2 BITE ADC-1:
ACA1R normal?
Check the impedance of
the transmitter's terminaĆ
tion if ACA1R is substanĆ
tially higher.
4.2.1
Adjustment erĆ
ror
Modulationdepthcorrectly
set?
- Mod. Depth 30 Hz AM
- Mod. Depth Voice AM
- Mod. Depth Identity AM
Correctlysetmodulation
depths.
4.2.2
Limiting in the
HF power secĆ
tion
CA-100 goes into limiting too
early.
TX1/2 BITE ADC-1:
ACM1 higher than normal?
Halve the set power "Carrier
Power":
- Mod. depth is increased:
- Mod. depth remains:
Replace CA-100*
CA-100*defective
Other fault
4.2.3
Carrier modulator MOD-110
goes into limiting.
TX1/2 BITE ADC-1:
ACM1 normal or lower?
Halve the set power "Carrier
Power":
- Mod. depth is increased:
- Mod. depth remains:
Replace MOD-110 (CSB)
MOD-110 (CSB) faulty
Other fault
4.3
Controlsignals
Control signal fromthe
MSG-S is not correct.
CSB_1_S2normal?
CSB_1_ST6normal?
If no, replace MSG-S.
4.3.1
VOR only
4.3.2
The modulation depth of the
identity is wrong or is missing.
TransmitterCommands:
- Is "Identity OFF"?
- Is Mod. Depth Identity AM
setcorrectly?
Set output power to 0.5 P
nom
:
- Is the identity then OK?
To recheck this, you may
need to set Ident CW-
Mode
Identity must be "ON".
If yes, CA-100* or
MOD-110 (CSB) are
overdriven; see 4.2.2 and
4.2.3.
Summary of Contents for DVOR 432
Page 2: ......
Page 4: ......
Page 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Page 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Page 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Page 46: ......
Page 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Page 74: ......
Page 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Page 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Page 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Page 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Page 194: ......
Page 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Page 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Page 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...