DVOR 432
Repairs
Operation and Maintenance
6-24
Ed. 01.04
JUMPER
POSITION
DEFINITION
REMARKS
X13
set
open
Switch off line TX1 fromLCP
Interrupt Switch off line TX1 fromLCP
default setting
X14
set
open
Switch off line TX2 fromLCP
Interrupt Switch off line TX2 fromLCP
default setting
X15
set
open
Line OP_IN- fromDME
Interrupt line OP_IN- fromDME
default setting
X16
not existing
X17
set
open
Test signal selection, ILS
Test signal selection, VOR/DVOR
default setting ILS
default setting (D)VOR
X18
set
open
Enabling cutoff for over-discharge protection
without over-discharge protection
Emergency battery operation
Operation without emergency
battery or function disabled
X19,29,21
Selection of battery type/cell voltage
only one jumper set simultan.!
X19
set
open
battery switch off at 1,7 V/cell
alternate to X20, X21
X20
set
open
battery switch off at 1,8 V/cell
alternate to X19, X21
X21
set
open
battery switch off at 1,875 V/cell
default setting
X22
set
open
enabling automatic restore
(power management)
-
with PMM-5 and (D)VOR
with PMM-5 and ILS
X23
set
open
no monitor fault monitoring MON2
monitor fault monitoring MON2
default setting
X24
set
open
no monitor fault monitoring MON1
monitor fault monitoring MON1
default setting
X25
1-2
2-3
DME-Status is transmitted via remote contr.
DME-Status is transmitted via signalling line
OP_IN+ and OP_IN-
depends on DME-Interface
X26
set
open
On/off line to optocoupler interface of BCPS
fromLCP via CSL closed
On/off line to optocoupler interface of BCPS
fromLCP via CSL open, e.g. if no emergency
battery exists
Default setting
(Power Management)
depends on installation
1
Control and Selector Logic (CSL)
83135 23100
2 of 2
Summary of Contents for DVOR 432
Page 2: ......
Page 4: ......
Page 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Page 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Page 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Page 46: ......
Page 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Page 74: ......
Page 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Page 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Page 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Page 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Page 194: ......
Page 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Page 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Page 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...