DVOR 432
Operation and Maintenance
Repairs
6-25
Ed. 01.04
V2
21
3
V3
V4
S1
2 1
3
X5
X8 X4
X7
X6
set
open
2 3
1
set
open
EPROM
EPROM
D8
D7
battery 3.6 V
+
-
-
JUMPER
POSITION
DEFINITION
REMARKS
X4
set
open
watch-dog fault triggers NMI
(Non Maskable Interrupt)
NMI function disabled
default setting
X5
2-3
1-2
EPROM type 27C040
EPROM type 27C020
default setting
X6
1-2
2-3
RAM type 628128
RAM-Typ 628512
default setting
X7
set
open
backup battery switched on
backup battery switched off
default setting
X8
set
open
multiple reset disabled, if watch dog fails
multiple reset enabled
default setting
2
Modulation Signal Generator Control (MSG-C) 83135 27200
Summary of Contents for DVOR 432
Page 2: ......
Page 4: ......
Page 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Page 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Page 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Page 46: ......
Page 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Page 74: ......
Page 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Page 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Page 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Page 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Page 194: ......
Page 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Page 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Page 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...