Menu/
INSTRUCTION
C: Commands
A: Activities
Submenu
DVOR 432
Operation and Maintenance
Alignment Procedure
Annex Nextfield
AN-29
Ed. 01.04
4.8.1.11
Identity AM Signal
(not applicable with Nextfield)
a) (Upper limit, e.g. 11.5 %.)
A/AL1
M1 Mod. Depth Iden-
tity AM UL --,- %
b) (Lower limit, e.g. 8.5 %.)
A/AL1
M1 Mod. Depth Iden-
tity AM LL --,- %
4.8.1.12
Alarm Delay
Set delay to e.g. 30 s.
A/AL1
M1 Alarm Delay
--- s
NOTE:
Range of values: 2...255.
4.8.2
Monitor 2
Set alarm limits for monitor 2 in the same way as described for
A/AL2
Alarm Limits M2
monitor 1 in section 4.8.1. Use Activity maskA/AL2 'Alarm Limits M2'.
4.9
BATTERY MONITORING
NOTE:
The floating battery must be installed and connected.
Use activities mask'BCPS/BAT'
A/BAT
a) Enter installed battery capacity.
A/BAT
Installed Batt. Capa
city
---.- Ah
b) When the Battery is fully charged, set 'Set Batt. Charge Level' to
A/BAT
Set Batt. Charge
the same value (Installed Capacity = Charge Level).
Level ---.- Ah
NOTE:
Divide Installed Capacity by 500 Ah. The battery is fully charged,
when 'battery current' indicates this value.
c) Checkalarm limits (UL and LL) for battery half voltage, battery full
A/BAT
Batt. half Voltage UL
voltage and battery current.
Batt. half Voltage LL
Batt. full Voltage UL
Batt. full Voltage LL
Batt. Current UL/LL
Summary of Contents for DVOR 432
Page 2: ......
Page 4: ......
Page 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Page 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Page 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Page 46: ......
Page 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Page 74: ......
Page 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Page 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Page 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Page 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Page 194: ......
Page 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Page 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Page 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...