BATTERY CHARGERS
5-2
Doc No. 84382 Rev 2
THALES COMMUNICATIONS, INC. PROPRIETARY INFORMATION
PHYSICAL CHARACTERISTICS
Weight and Dimensions
The charger weights and dimensions are shown below:
Table 5-2 Battery Charger Weights and Dimensions
Charger
Configuration
Part
Number
Weight (excluding power
cord or vehicle adapter)
Size (excluding power
cord)
Standard Single Unit
Charger
1600682-1
< 2 pounds
Approx. 5.0 inches (W) x 4.0
inches (H) x 4.0 inches (D).
Temperature
The chargers’ charging and storage temperature ranges are shown below:
Table 5-3 Charging and Storage Temperatures
Descriptions
Temperature
Charging Temperature Range
-10°C (+14°F) to +55°C (+131°F)
Storage (Non-operational) Temperature Range:
-40°C (-40°F) to +85°C (+185°F)
Attempting to charge batteries outside the operating temperature range can result in damage to both the
chargers and batteries.
ELECTRICAL CHARACTERISTICS
Table 5-4 Charging and Storage Temperatures
Charger Type
Electrical Characteristics
Single Unit Charger
90 to 264 VAC, 47-63 Hz
PERFORMANCE
Battery charge time can be affected by various conditions, such as the charger input current. When
inserting a battery, make sure it is firmly seated in the charger. The battery chargers communicate with the
circuitry in the battery to monitor charge current, temperature, and voltage to prevent improper charging.
Indicator LED’s on the chargers provide status.
Table 5-5 Charger Performance
Charger Configuration
Capacity
Charge Time
Single Bay AC
One battery pack
Three hours