background image

4.G.4B

B

A

C

All front nogs 
to be installed 
on edge

Air 
Vents

Note:

 these dimensions are the absolute minimum sizes - 

widths (A & C) maybe increased if desired. It is important to 
ensure the Jetmaster firebox is seated on top of the finished 
floor protector level.

Fig. 3

*Allow temporary lintel height until firebox & flue is installed

Table 4

TRIM OUT DIMENSIONS

Dimensions in mm

MODEL

A

B

C

Temporary 

Lintel*

700

850

730

450

1200

850

1000

730

450

1200

1050

1200

650

450

1200

1200

1350

650

450

1200

1500

1650

650

450

1200

GAS TRAY OPERATING OPTIONS

* M.V. - Millivolt: no electricity required

SFB / DLX

Manual

*M.V. Wall Switch

700

850

1050

1200

1500

Table 2

MODEL

Gas Input MJ/Hr

NG

LPG

700 SFB

45

38

850 SFB

50

43

1050 SFB

65

65

1200 SFB

75

70

1500 SFB

85

80

GAS INPUT

Table 3

Summary of Contents for JETMASTER 700

Page 1: ... Fig 1 IMPORTANT Read all instructions carefully before starting installation Failure to follow these instructions may result in a fire hazard and will void the warranty This appliance must be serviced every 12 months by a registered gas fitter Model A A1 A2 B C D E F G Y 700 700 800 750 341 650 290 200 250 630 265 235 850 850 950 900 341 650 290 250 300 630 265 235 1050 1050 1150 1100 341 570 290...

Page 2: ... lintel height until firebox flue is installed Table 4 TRIM OUT DIMENSIONS Dimensions in mm MODEL A B C Temporary Lintel 700 850 730 450 1200 850 1000 730 450 1200 1050 1200 650 450 1200 1200 1350 650 450 1200 1500 1650 650 450 1200 GAS TRAY OPERATING OPTIONS M V Millivolt no electricity required SFB DLX Manual M V Wall Switch 700 850 1050 1200 1500 Table 2 MODEL Gas Input MJ Hr NG LPG 700 SFB 45 ...

Page 3: ... rodent proof 4 If intending to recess the firebox the maximim recess value is 100mm Refer to Fig 7 5 If a On Off Wall Switch is being installed a power cable 3m supplied must be run from the on off switch to the firebox Gas Models 1050 1200 1500 are operated by a Millivolt power source DO NOT connect a 240V supply to these gas burners see table 2 for full details If a wall switch is being install...

Page 4: ...e cement exhaust cement and bolts supplied to the convector box Note Pop rivet back of gather to convector box if required 2 Locate and position convector box and gather in cavity 3 Earthquake restraints holes are located under the cover where the receiver and battery pack are situated 4 Attach rock wool to the sides back of the convector box and gather DO NOT BLOCK OFF the air entry between the i...

Page 5: ... from combust material Allow gas line into firebox Non combustible material Promina Eterpan LD Supalux maximum 100mm recessed allow 2mm minimum space away from firebox Hebel Block 200 300 200 min 2 x 80mm diam equal square or rectangle shape area wall or floor mounted air vents 6mm Hardiflex Rock wool insulation Gib Floor Protector min 50mm from combust material 6mm Hardiflex Allow gas line into f...

Page 6: ...e flue is required to be at least 500mm above the nearest point on any part of the buildings roof and neighbouring buildings if within a 3m radius Refer to NZS 5261 2003 2 6 13 for further information 7 The last length of flue pipe needs to extend past the flue pipe casing by at least 150mm or flush with the top of the casing cover spigot when fitted sizing measuring and cutting down should be car...

Page 7: ...ns must be bird rodent proofed with permanently fixed screens Drawing Not To Scale Fig 10 FLUE PENETRATION EXTERNAL REQUIREMENTS Refer to NZS5261 2003 or less Any nearby structure 1000 1000 500 500 min 200 between flue terminals increase as necessary until nothing within 500mm of flue terminal end of the flue shall be at least 500mm from the nearest part of the roof MINIMUM HEIGHT OF FLUE SYSTEM E...

Page 8: ... 25 45 50 90 100 150 170 200 250 300 350 100 200 300 400 500 230 320 380 425 460 483 X Y X Y X Y Flue Pipe Min 25mm Clearance Min 25mm Clearance Flue Pipe Casing Fig 12 Table 5 Note A minimum 25mm clearance from flue pipe casing to combustible material must be maintained Dimensions in mm CHIMNEY CHASE MINIMUM TRIM OUT MODEL FLUE SYSTEM MINIMUM TRIM OUT DIMENSION X min Y min 700 200 250 300 300 850...

Reviews: