16
ENGLISH
TROUBLESHOOTING GUIDE
BE SURE TO FOLLOW SAFETY RULES AND INSTRUCTIONS
For assistance with your product, visit our website at
www.thefountainheadgroup.com
or call 1-800-311-9903.
PROBLEM
POSSIBLE CAUSE
SOLUTION
The sprayer does not turn
ON (no audible hum of
the pump).
Ensure the battery is correctly
installed.
Install the battery correctly. See
Installing
the Battery.
Ensure the battery is charged.
Charge the battery. See
Charging the
Battery.
The battery may be damaged or
may have overheated. Visually
inspect the battery for damage.
Replace the battery if it is damaged or not
working. If the battery overheated, allow
the battery to cool.
The hose is pressurized. The pump
turned OFF automatically.
Squeeze the shut-off lever to see if the
sprayer starts and the pump turns ON.
The sprayer turns ON
(pump head hums) but it
will not spray.
There is no liquid in the tank.
Add liquid to the tank. See
Filling the
Sprayer
.
The shut-off filter is clogged.
Clean the shut-off filter. See
Shut-off
Assembly Maintenance
.
The nozzle is clogged.
Clean the nozzle. See
Nozzle Maintenance
.
The in-tank filter is clogged.
Clean the in-tank filter. See
In-Tank Filter
Maintenance.
The pump is not primed.
Allow at least 30 seconds for the pump
to prime.
The sprayer turns ON
but only sprays at low
pressure.
The shut-off filter is clogged.
Clean the shut-off filter. See
Shut-off Assembly Maintenance
.
The nozzle is clogged.
Clean the nozzle. See
Nozzle Maintenance
.
The in-tank filter is clogged.
Clean the in-tank-filter. See
In-Tank Filter
Maintenance.
The pump is not primed.
Allow at least 30 seconds for the pump
to prime.
The pump does not fully
prime.
The liquid level in the tank is low.
Add liquid to the tank. See
Filling the
Sprayer
.
The pump was run dry (without
liquid) before the tank was refilled.
Ensure the sprayer is OFF and squeeze the
shut-off lever until all pressure is relieved.
There is chemical residue or build-
up in the tank and/or pump due to
improper or inadequate cleaning.
Clean the sprayer. See
Cleaning
. If
necessary, repeat with warm water and a
mild detergent mixture. Allow the mixture
to stay in the pump for up to 1 hour prior
to rinsing. Replace the pump if necessary.
The in-tank filter is improperly
installed, missing, or damaged,
allowing debris to enter the pump.
Clean the sprayer. See
Cleaning
. If
necessary, repeat with warm water and a
mild detergent mixture. Allow the mixture
to stay in the pump for up to 1 hour prior
to rinsing. Replace the pump if necessary.
The hose leaks at the tank
connection.
The hose is cracked, swollen, or
faulty.
Replace the shut-off assembly.
The connection is damaged.
Replace the shut-off assembly