background image

Fan Installation 

(continued)

6

Carefully turn fan assembly over and place face 

down on either piece of packing foam. Remove the 

stopper screw and loosen the set screw on the fan 

collar. Set the stopper screw aside for Step 8.

Run fan wires through selected down rod. Reinstall

stopper screw from Step 6 and firmly tighten set 

screw on fan collar against down rod.
Note:

 If ceiling height allows, using a longer down 

rod will increase airflow and efficiency.

Slide fan canopy over down rod and carefully rest 

on top of fan body.

6

8

9

Reinstall half ball on end of down rod. Be sure 

that stopper pin is inserted through down rod 

and seated in half ball. Tighten set screw against 

down rod.

10

set screw

stopper screw

Remove stopper pin and half ball from small down 

rod by loosening set screw on half ball. Set all 

parts aside for Step 10.

7

set screw

stopper pin

Feed bridge connector through 

center hole of LED board and 

carefully insert two-pin connector into

terminal on the LED board. Gently 

push excess wire behind light cup 

and place LED board flat on

light plate with cutouts positioned 

over the three attachment holes.
Align LED cover with fastening holes 

positioned over cutouts in LED 

board and attachment holes on light 

plate. Use short panhead screws to

secure LED cover and LED board in 

place on light plate.

WARNING

See Page 2

POWER OFF

Circuit Breaker

Summary of Contents for Plum

Page 1: ...duct versions and configurations and the associated installation steps If your fan or parts of your fan do not appear to match what is included here please contact customer service for guidance and support in identifying which version of a fan you may have and provision of the associated installation instructions which correspond to that version If in doubt or if you have any questions at all rela...

Page 2: ...m Installation Instructions and Owners Manual Customer Service Monday Friday 8am 4pm PST tel 888 588 3267 Safety Instructions and Warnings 2 Fan Installation 4 Control Installation and Wiring 8 Troubleshooting 12 Maintenance 14 Warranty 15 Models PLU XX XX XX XX X XXX Net Weight of Fan 14 lbs 6 4 kgs V2020 08 ...

Page 3: ...able for Fan Support and use mounting screws provided with the outlet box Note Most outlet boxes commonly used for light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Prior to installation or servicing always disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you can...

Page 4: ...ol must be grounded using the attached green wire After making wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box This device complies with Par...

Page 5: ...A stepladder phillips head screwdriver and a wire stripper Optional Light Kit parts light plate LED board hardware screws bridge connector LED cover glass diffuser blades canopy fan body bottom cap balancing kit hanging bracket hardware package rotor optional control half ball down rods ...

Page 6: ...he notches in the center hub Carefully set rotor and blade assembly on motor so that attachment tabs are positioned over motor holes Secure rotor to motor using the four screws from Step 3 If installing optional 271 LED Light Kit follow the steps below Otherwise skip this section and proceed to Step 6 Note If the parts you received are different than what is listed pictured here you may have a pri...

Page 7: ...at stopper pin is inserted through down rod and seated in half ball Tighten set screw against down rod 10 set screw stopper screw Remove stopper pin and half ball from small down rod by loosening set screw on half ball Set all parts aside for Step 10 7 set screw stopper pin Feed bridge connector through center hole of LED board and carefully insert two pin connector into terminal on the LED board ...

Page 8: ...ceiling fan Furthermore a blade balancing kit has been included with your fan Please refer to the instructions packaged with the balancing kit should your fan require additional balancing Install bottom cap if your fan does not have a light kit or the glass diffuser if your fan does have a light kit In either case rotate clockwise until cap or diffuser comes to a stop Install wall control as descr...

Page 9: ...signed for independent operation of a fan and light using only one circuit two wires Provides three speeds and full range dimming or on off switching and wires into wall box Includes wall control switch plate and receiver FC 003 LED Handheld Remote Control Designed for independent operation of a fan and light using only one circuit two wires Provides three speeds and full range dimming or on off s...

Page 10: ...ht Black to motor Blue to light Fan Control FC 003 004 005 Wiring Diagram Green ground White neutral motor Black motor White Black Blue light Fan Receiving Unit Green ground connect ground wire to grounded hanging bracket or mounting plate Green ground connect ground wire to grounded hanging bracket or mounting plate Green ground connect ground wire to grounded hanging bracket or mounting plate Or...

Page 11: ... 004 and 005 only With fan suspended from ceiling and with power off at breaker box make wire connections as shown below Receiving Unit Placement The receiving unit sits in the ball hanging bracket as shown below While there is ample room for the receiving unit as shown here the wires can sometimes become difficult to manage in the space available Trimming excess wire before making connections can...

Page 12: ...e light Pressing and releasing the LIGHT button will turn the light on and off Pressing and holding the LIGHT button will increase or decrease brightness continuously until you let go of the button To disable dimming function on either the wall control or the remote handset move the dip switch es pictured here from Dim to On Off or from Dim to On These dip switches are located inside the battery c...

Page 13: ... matched when packaged together Please read all installation instructions carefully After reviewing the following troubleshooting tips if you are unable to solve a problem with the installation or operation of you fan please contact customer service for additional assistance Important Do not return a fan or fan parts without first contacting us for troubleshooting assistance If we are unable to re...

Page 14: ...moval and re attachment can sometimes remedy such resonant vibrational noise Fan or light not responding to hand held remote or wall mounted RF signal Check that all wire connections are secure and made as instructed Verify that power is on and reaching the receiver using a voltmeter Review and repeat pairing instructions Be sure to firmly press the center area of the buttons on you handset or wal...

Page 15: ...deterioration or oxidizing effects of salt or other corrosive elements A Damp Location rating is not an assurance of finish durability Preventative measures should be taken dependent on the environmental exposures your fan will undergo in order to preserve and protect the finish quality and appearance of your fan If a wobble develops over time you may need to rebalance your fan following the instr...

Page 16: ...This warranty only covers the replacement or repair of ceiling fan or parts as specified above and does not cover any other costs incurred related to installation labor or equipment or shipping of fan or fan parts No other expressed warranty is given The repair or replacement of a product is your exclusive remedy Any implied warranty of merchantability or fitness is limited to the dura tion of thi...

Page 17: ...V2020 08 The Modern Fan Company Inc 709 Washington Street Ashland Oregon 97520 tel 888 588 3267 fax 541 482 8418 info modernfan com modernfan com ...