background image

1

SELEKTA 171 top2 RC 24 V

1714100

SELEKTA 172 top2 24 V

1724100

307112

Astronomical time switch

EN

1.  Basic safety information

Danger of death through electric shock or fire!

¾

¾

Installation should only be carried out by a 

qualified electrician!

WARNING

 

The device is designed for installation on DIN top hat 
rails (in accordance with EN 60715)

 

Power reserve (10 years) is reduced if memory card is 
inserted (using battery power)

 

The device corresponds to type 1 BSTU in accordance 
with IEC/EN 60730-2-7

 

3 special programs with date function per channel

 

Time synchronisation via connection of an external DCF 
antenna (SELEKTA 171 top2 RC 24 V)

 

!

OBELISK top2 memory card: Avoid mechanical stress or 
contamination during storage/transportation

2.  Proper use

 

The astronomical time switch is used, for instance, for 
lighting equipment (roads, external staircases, display 
windows, entrances etc.)

 

Only for use in closed, dry rooms 

 

!

Do not use on safety devices, e.g. escape route doors, fire 
safety equipment etc.

Disposal

¾

†

Dispose of device in environmentally sound manner 

3.  Installation and connection

Danger of death through electric shock or fire!

¾

¾

Installation should only be carried out by a 

qualified electrician!

WARNING

 

Mounting the time switch

click

45° cable

Load line 

connection 

opener

Test tap

DuoFix

®

 plug-in 

terminal

¾

†

Mount on DIN top hat rail (as defined in EN 60715)

¾

†

Disconnect power source

¾

†

Ensure device cannot be switched on

¾

†

Check absence of voltage

¾

†

Earth and bypass

¾

†

Cover or shield any adjacent live components

Connecting the cable

C1

1 2 3

– +

Ext1

max.

 100 

m

Data

RC DCF

12-24 V

+

~

–~

+

~ –~

C2

C1

1 2 3

4 5 6

Ext1

max.

 100 

m

max.

 100 

m

Ext2

12-24 V

+

~

+

~

–~

–~

SELEKTA 172 top2 24 V

SELEKTA 171 top2 RC 24 V

100 m

Summary of Contents for 1714100

Page 1: ...oper use The astronomical time switch is used for instance for lighting equipment roads external staircases display windows entrances etc Only for use in closed dry rooms Do not use on safety devices...

Page 2: ...NU Activate display Open menu Cancel menu ESC leave menu OK Save selection Confirm selection Options are displayed 0 6 12 18 24 Time display Sunrise sunset display Date display Channel status C1 C2 ON...

Page 3: ...alue can be used to shift the calculated astro times by 120 min This means that the astro turn on and turn off times can be adapted to local conditions e g mountains high buildings etc or to personal...

Page 4: ...3 types of date areas Fixed date area e g starting time on 2015 04 02 at 04 00 p m end time on 2015 04 24 at 10 00 a m Yearly repeating date area e g Christmas starting time on 24 12 at 06 00 p m ever...

Page 5: ...HOLIDAY END Press MENU Select MANUAL and press OK to confirm Select CHANNEL confirm with OK Select PERM ON or PERM OFF and press OK to confirm Setting holiday function MANUAL MENU u CHANNEL C1 u PERM...

Page 6: ...ously for 2 seconds Cancelling manual permanent switching Press both buttons simultaneously Hour counter The operating hours of the channel relay are displayed and deleted in the OPTIONS menu If the n...

Page 7: ...ta Operating voltage 12 24 V 50 60 Hz 10 15 12 24 V DC 10 15 Standby 0 9 W 1714100 0 2 W 1724100 Switching capacity max 16 A at 250 V AC cos 1 Switching capacity 2 A at 250 V AC cos 0 6 Switching capa...