7
Risk of electric shock!
The device does not have basic insulation around the termi
-
nals/plugs!
¾
Protect against accidental contact during installation.
¾
Maintain a minimum distance of 3 mm from live parts or
use additional insulation, e.g. separating strips/walls.
¾
Always operate electronic and conventional transformers
with the minimum load specified by the manufacturer.
¾
Only use dimmable LED lamps, as normal LED lamps may
be destroyed.
¾
When changing the lamps, switch off the power supply
(at the fuse box) so that the automatic load detection is
reactivated.
¾
Do not connect dimmer load connections (L´) in parallel.
¾
Do not bypass or short-circuit the dimmer.
¾
Do not install any isolating or variable transformers before
the dimmer.
¾
Do not mix wound and electronic transformers in the
installation.
¾
Do not mix wound transformers and LEDs in the
installation.
¾
Do not connect buttons with glow lamps.
¾
Correct automatic load detection is only possible with a
connected load.
¾
Only use transformers approved by the manufacturer for
dimmer operation.