26
Time signal can be received with
appropriate top3 RC antenna
(only with TR 611 top3 RC)
L
Refer to operating instructions 310336 when connecting a
GPS antenna (9070610).
L
Follow the advice in the top3 RC-DCF antenna operating
instructions.
L
Connection to the top3 RC-DCF antenna allows the time
switch to be automatically synchronised via DCF signal.
L
After connecting to the power supply or resetting, the
automatic display appears as soon as the DCF transmis-
sion signal has been received.
Adjusting of time zones
After successful synchronisation, the time zone can be altered
in the TIME/DATE menu option.
¾
In the TIME menu (display: MODIFY HOUR) correct the
applicable local time (time zone).
MENU
OK
theben
0
6
12
18
24
110-230V~
50-60Hz
R 10a - 30T
16(10)A 250V~
1
C1
2
3
Ext
Data
L
N
TR
61
1
top3
µ
RC
max.100 m
DCF transmission signal
reception:
Display:
Day + Month + RC
(Radio Control)
No reception of the DCF
transmission signal
Display:
e.g. 24 11 07
No connection to antenna:
Display:
e.g. 24 11 07