APPENDIX A – WIND WARNING
Additional Venting Problems
Occasionally, the vent configuration can create a
noisy, harmonic condition. This sound can be
eliminated by closing the air damper located on the
air intake tube on the rear of the stove (see FIGURE
2).
This Thelin Pellet Stove is equipped with a blocked
flue/high temp safety sensor that will shut the stove
off if there is a down draft, blocked flue, or high
temperature condition.
If installing the stove on the side of the house that is
hit by prevailing winds (usually 30 to 40 mph or
greater) there is a chance that the sensor will be
activated and the stove will shut off. Should this
occur, run the pipe up vertically through the eave
and use a high wind cap on the vertical termination
(see diagram).
Contact your Dealer if you have any questions
about this potential problem.