PARLOUR PELLET 3000
PELLET HEATER
16
battery attached. Battery will drain
down and fail to recharge
.
6.
If you choose to separate the battery from the
heater by lengthening the cables, you must make
sure the cable used will carry the current to the
heater. For example, if the distance is 10 to 20
feet, then 12-gauge wire must be used. Check
with your local electrical professional to make
sure you have used the proper gauge wire/cable.
7.
The automatic ignition feature will not work on
DC power only. The stove can be lit manually
with an approved starter material. Call Thelin if
you need help with manual lighting.
FIGURE 14
MAINTENANCE PROCEDURES
CAUTION
: Moving parts may cause injury. DO
NOT operate with rear cover removed.
WARNING
: Risk of electrical shock. Disconnect
all power before servicing.
Always turn your heater off and let it cool before
cleaning.
Your Parlour Pellet Heater requires routine
maintenance for maximum performance, and it is
mandatory for the warranty to remain in effect.
The following procedures should be studied
carefully and performed regularly as indicated.
a.
Soot and Fly Ash: Formation and Removal.
The products of combustion will contain
small particles of fly ash. The fly ash will
collect in the exhaust venting system and
restrict the flow of the flue gases.
Incomplete combustion, such as that which
occurs during start-up, shut down, or
incorrect operation of the room heater will
lead to some soot formation which will
collect in the exhaust venting system. The
exhaust venting system should be inspected
at least once a year or immediately
following the heating season to determine if
cleaning is necessary.
b.
When the heater is shut down and cold, you
should open door and remove clean out
cover. To remove, simply lift up and out
from retaining notched cutout on vertical
wall (see Figure 14). Clean one side at a
time. With one cover removed, leave the
door open 1" and push the “Clean” button.
Let heater run 30 seconds, push to “Off,”
and replace cover. Remove the remaining
clean out cover and repeat procedure for
other side.
Disposal of Ashes: Ashes should be placed
in a metal container with a tight-fitting lid.
The closed container of ashes should be
Summary of Contents for PARLOUR 3000
Page 4: ...PARLOUR PELLET 3000 PELLET HEATER 4 of 31 LABORATORY LISTING LABEL...
Page 20: ...PARLOUR PELLET 3000 PELLET HEATER 20 FIGURE 15 REPLACEMENT PARTS LIST 16...
Page 25: ...PARLOUR PELLET 3000 PELLET HEATER 25 APPENDIX B E I FIREPOT ASSEMBLY...
Page 26: ...PARLOUR PELLET 3000 PELLET HEATER 26 APPENDIX B OUTSIDE AIR HOOK UP...
Page 29: ...PARLOUR PELLET 3000 PELLET HEATER 29 APPENDIX E REPLACEMENT OF IGNITER...