Solution
: If the heater emits smoke during a
power failure and you have frequent power
failures, then we suggest you purchase the
battery back-up system. If the vent pipe is
installed according to these instructions, the
smoke will siphon out of the pipe in most
instances.
6.
Problem
: After several weeks of outstanding
performance, the heater suddenly stopped and
the red light under the control panel came on.
This light is the High Temp/Flue indicator light.
Solution
: The High Temp/Flue indicator light
indicates that fly ash has built up in the exhaust
system and/or there is a restriction in the
exhaust/flue system. Check the pipe system for
excessive ash and clogging, particularly the vent
cap. Remove the clean out cap on the tee and
make sure that ash has not blocked the exhaust
air flow. This automatic shut down in case of
flue clogging is a safety feature, and if the shut
down occurs it means you have a problem and
should consult a service technician and/or clean
your pipe and heater thoroughly. If you feel the
fly ash build-up is excessive, we suggest you try
another pellet brand. In most climates the pellets
and fly ash can absorb moisture from the air and
create creosote and a severe clogging problem.
Keep this in mind when you store and handle
your pellets. The heater warranty does not cover
the quality of the fuels used or the way they may
be handled, either before or after you've
purchased them.
7.
Problem
: I turned off the switch and the heater
continued running.
Solution
: This is normal. The exhaust blower
will keep running until it cools down and then it
will automatically turn off. This can vary by the
temperature the exhaust has reached and the
temperature of the cooling air.
8.
Problem
: Fan motor speed varies, sometimes
running low and sometimes surging. Will run on
"High" or "Clean" but not on "Low."
Solution
: Fan motor brushes are wearing out.
Brushes in fan motor need to be replaced.
Contact your dealer or call factory for
replacement brushes.
9.
Problem
: Stove shuts off at night when running
on low.
Solution
: Feed is to low. Adjust feed trim
button (turn clockwise) until feed can maintain
fire.
10.
Problem
: I see a flashing green light behind the
outer shield. What does this mean?
Solution
: The flashing green light behind the
outer shield means the circuit board is
energized. This is okay. “Green means go.” All
systems are ready and operational.
Summary of Contents for PARLOUR 3000
Page 4: ...PARLOUR PELLET 3000 PELLET HEATER 4 of 31 LABORATORY LISTING LABEL...
Page 20: ...PARLOUR PELLET 3000 PELLET HEATER 20 FIGURE 15 REPLACEMENT PARTS LIST 16...
Page 25: ...PARLOUR PELLET 3000 PELLET HEATER 25 APPENDIX B E I FIREPOT ASSEMBLY...
Page 26: ...PARLOUR PELLET 3000 PELLET HEATER 26 APPENDIX B OUTSIDE AIR HOOK UP...
Page 29: ...PARLOUR PELLET 3000 PELLET HEATER 29 APPENDIX E REPLACEMENT OF IGNITER...