background image

PARLOUR PELLET 3000 

PELLET HEATER 

 

 

 

19 

Solution

:  If  the  heater  emits  smoke  during  a 

power  failure  and  you  have  frequent  power 
failures,  then  we  suggest  you  purchase  the 
battery  back-up  system.  If  the  vent  pipe  is 
installed  according  to  these  instructions,  the 
smoke  will  siphon  out  of  the  pipe  in  most 
instances. 

6.

 

Problem

:  After  several  weeks  of  outstanding 

performance,  the  heater  suddenly  stopped  and 
the  red  light  under  the  control  panel  came  on. 
This light is the High Temp/Flue indicator light. 

Solution

:  The  High  Temp/Flue  indicator  light 

indicates that fly ash has built up in the exhaust 
system  and/or  there  is  a  restriction  in  the 
exhaust/flue  system.  Check  the  pipe  system  for 
excessive ash and clogging, particularly the vent 
cap.  Remove  the  clean  out  cap  on  the  tee  and 
make  sure  that  ash  has  not  blocked  the  exhaust 
air  flow.  This  automatic  shut  down  in  case  of 
flue clogging is a safety  feature, and if the shut 
down  occurs  it  means  you  have  a  problem  and 
should consult a service technician and/or clean 
your pipe and heater thoroughly. If you feel the 
fly ash build-up is excessive, we suggest you try 
another pellet brand. In most climates the pellets 
and fly ash can absorb moisture from the air and 
create  creosote  and  a  severe  clogging  problem. 
Keep  this  in  mind  when  you  store  and  handle 
your pellets. The heater warranty does not cover 
the quality of the fuels used or the way they may 
be  handled,  either  before  or  after  you've 
purchased them. 

7.

 

Problem

: I turned off the switch and the heater 

continued running. 

Solution

:  This  is  normal.  The  exhaust  blower 

will keep running until it cools down and then it 
will automatically turn off. This can vary by the 
temperature  the  exhaust  has  reached  and  the 
temperature of the cooling air. 

8.

 

Problem

:  Fan  motor  speed  varies,  sometimes 

running low and sometimes surging. Will run on 
"High" or "Clean" but not on "Low." 

Solution

:  Fan  motor  brushes  are  wearing  out. 

Brushes  in  fan  motor  need  to  be  replaced. 
Contact  your  dealer  or  call  factory  for 
replacement brushes. 

9.

 

Problem

: Stove shuts off at night when running 

on low. 

Solution

:  Feed  is  to  low.  Adjust  feed  trim 

button  (turn  clockwise)  until  feed  can  maintain 
fire. 

10.

 

Problem

: I see a flashing green light behind the 

outer shield. What does this mean? 

Solution

:  The  flashing  green  light  behind  the 

outer  shield  means  the  circuit  board  is 
energized. This is okay. “Green means go.” All 
systems are ready and operational. 

Summary of Contents for PARLOUR 3000

Page 1: ...NS CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION AND PERMIT REQUIREMENTS FAILURE TO COMPLY WITH OWNER S MANUAL INSTRUCTIONS WILL VOID WARRANTY AND COULD RESULT IN PRO...

Page 2: ...Exchanger 15 High Temp Flue Indicator Light 13 Hopper clean out 15 filling 11 Installation 7 battery 13 clean out tee 8 distance to openings 8 floor protection 7 pipe configuration 7 pipe connections...

Page 3: ...tion Rear View 8 Figure 4 9 Figure 5 9 Figure 6 10 Figure 7 10 Figure 8 11 Figure 9 12 Figure 10 13 Figure 11 13 Figure 12 14 Figure 13 16 Figure 14 Replacement Parts List 20 Figure 15 Circuit Board D...

Page 4: ...PARLOUR PELLET 3000 PELLET HEATER 4 of 31 LABORATORY LISTING LABEL...

Page 5: ...pliance and components for damage Damaged parts may impair safe operation DO NOT install damaged components DO NOT install incomplete components DO NOT install substitute components Report damaged par...

Page 6: ...ontact your local dealer if assistance is required before during and after installation Before Start Up Check List 1 All Safety Warnings have been read and followed 2 The Owner s Manual has been read...

Page 7: ...ccessibility clearance for servicing and proper operation Never obstruct the front opening of the heater The heater may be installed as a free standing unit mounted on a non combustible protective flo...

Page 8: ...be provided for combustion and ventilation air The air inlet must remain unrestricted while unit is in use Outside air connection is located at the bottom near the front of the heater see Figure 2 Th...

Page 9: ...d so that access is provided for inspection and cleaning 2 Avoid installing heater in high traffic areas Keep children away from heater when in operation 3 Outside air required see Figure 10 4 A 3 inc...

Page 10: ...If there is a power failure the heater will shut down If the 12 volt back up system is installed the heater will automatically switch to the 12 volt power Route the power supply cord so it does not t...

Page 11: ...al see Figure 10 Follow thermostat manufacturer s instructions 3 Locate thermostat approximately 10 to 12 feet from heater or in an area that requires steady temperature Run thermostat wires from heat...

Page 12: ...PARLOUR PELLET 3000 PELLET HEATER 12 FIGURE 10 Fuse Holder To remove fuse push cap in and turn counter clockwise Rotated and enlarged view of plate bottom Outside Air Hook Up...

Page 13: ...pot must be seated flush and must sit even in the fire pot tray Air leakage around the fire pot will create a poor burn see Figure 12 In case of power outage with battery connected light the pellets i...

Page 14: ...of pellets per hour The flame will fluctuate from 3 to 8 inches in height 4 In the High position the Parlour will feed approximately 5 pounds of pellets per hour The flame will fluctuate between 3 in...

Page 15: ...lour Pellet 12V back up can be purchased as an option and includes the following components a Deep cycle seated 12 volt gel cell battery available at most battery stores b Battery connector cables for...

Page 16: ...ffect The following procedures should be studied carefully and performed regularly as indicated a Soot and Fly Ash Formation and Removal The products of combustion will contain small particles of fly...

Page 17: ...saw dust in the hopper weekly Keep free of debris and foreign material An accumulation of saw dust can cause irregular pellet feed For best results this should be done on a regular basis depending on...

Page 18: ...d check the feed chute to see what is causing the jam Remove any foreign material or object and restart the heater CAUTION Keep fingers and hands clear of the feed mechanism when heater is on 3 Proble...

Page 19: ...t you try another pellet brand In most climates the pellets and fly ash can absorb moisture from the air and create creosote and a severe clogging problem Keep this in mind when you store and handle y...

Page 20: ...PARLOUR PELLET 3000 PELLET HEATER 20 FIGURE 15 REPLACEMENT PARTS LIST 16...

Page 21: ...PARLOUR PELLET 3000 PELLET HEATER 21 FIGURE 17 CIRCUIT BOARD DIAGRAM Type 2 Thermostat High Low Type 1 Thermostat On Off 17 0...

Page 22: ...PARLOUR PELLET 3000 PELLET HEATER 22 FIGURE 18 ELECTRICAL SCHEMATIC WIRING DIAGRAM 250 VAC 250 VAC...

Page 23: ...ot use a household vacuum cleaner 4 Connect vinyl clean out tube to pellet vac or shop vac An adaptor must be used to connect to a shop vac These can be purchased at hardware stores or home centers In...

Page 24: ...equipped with a blocked flue high temp safety sensor that will shut the stove off if there is a down draft blocked flue or high temperature condition If you install the stove on the side of the house...

Page 25: ...PARLOUR PELLET 3000 PELLET HEATER 25 APPENDIX B E I FIREPOT ASSEMBLY...

Page 26: ...PARLOUR PELLET 3000 PELLET HEATER 26 APPENDIX B OUTSIDE AIR HOOK UP...

Page 27: ...ellet and longer than 1 then the stove could go out on the low setting for lack of fuel Turn the trim clockwise to increase fuel and thus sustain the fire 2 The Fan Trim Pot Adjustment is located on t...

Page 28: ...em 4 in illustration 5 Vertical termination cap type L pellet must be used on all installations If wind conditions are present then utilize a high wind cap see item 5 in illustration PELLET QUALITY Ve...

Page 29: ...PARLOUR PELLET 3000 PELLET HEATER 29 APPENDIX E REPLACEMENT OF IGNITER...

Page 30: ...amages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights that vary from state to state WARRANTY WORK If you find this unit to be defective in mate...

Page 31: ...PARLOUR PELLET 3000 PELLET HEATER Thelin Hearth Products Inc 63 Laxalt Dr Carson City NV 89706 www thelinco com...

Reviews: