FIGURE 19 – ROUTINE STOVE CLEAN OUT AND MAINTENANCE
The following is a step-by-step procedure to clean out and maintain your pellet stove.
1.
Stove must be shut off and completely cold before performing this maintenance
.
2.
Open door; remove fire pot and clean-out covers.
3.
Vacuum entire inside area, including heat exchanger tubes, using a pellet vac or shop vac.
Do not
use a household vacuum cleaner
!
4.
Connect vinyl clean-out tube to pellet vac or shop vac. (An adaptor must be used to connect to a
shop vac. These can be purchased at hardware stores or home centers.) Insert the clean-out tube
down between the heat exchange tubes (approx. 4” to 6”) as shown in the picture, and vacuum up the
debris. Reposition the tube several times to get as much debris as possible. Repeat the procedure at
the other set of tubes.
Remove vinyl clean-out tube.
5.
Turn control knob to “clean” position for about 45 seconds.
6.
Replace clean-out covers and fire pot. The stove is now ready to use.