background image

05

Installation Guidelines

06

Product Instructions

Maintenance

Function Description

1)Power Switch

    a.  Press to turn on/off
    b.  When the machine is turned on, the air valve stepping motor starts and 
         the air outlet opens
    c.  When off, the air valve stepping motor starts and the outlet closes
    d.  Press and hold the power switch for 3 seconds to turn on/off PTC 
         (Electric Auxiliary Heating)

2)Air Speed Button

    Press the air speed button, the fan will cycle between the speeds (under 
    power-on condition)

3)Reset Button

    a.  Short press is invalid, shutdown status is invalid
    b.  Press and hold the button for 3 seconds to reset the filter timing (under 
         power-on condition)

According to the needs of purification and fresh air, choose a suitable place 
to place and install it by professional installation personnel. When the  
machine is placed, it shall be ensured that the machine is installed smoothly 
on the wallbracket and that the fresh air outlet on the back of the machine is 
well connected withthe fresh air duct.

1. Turn on the power and press the power switch to start the machine. The 
    default mode is mid-speed/no electric auxiliary heating.
2. In the power-on state, every time you press the air speed button, the 
    machine will becycled between the three air speed, and the corresponding 
    LED indicator lights up synchronously.
3. In the power-on state, press and hold the power button for 3 seconds to 
    turn on/off the electric auxiliary heating function. The default is off.

Warning: The following installation must be performed by professionals.

1. First drill a large through hole (Ø130MM) and four expansion screw holes 
     (Ø6mm) in the designated position on the wall.
2. According to the thickness of the wall, adjust the total length of the fresh air 
    duct, insert the fresh air duct from the house, and tighten the flange.
3. Use the expansion screws in the accessory package to install the wall bracket 
    on the wall, and install the M4*8 machine screws on the wall bracket.
4. Insert the power cord into the ventilator unit, and install the unit on the wall 
    bracket steadily to ensure that the fresh air outlet and the fresh air duct are well 
    connected. Turn on the machine, run and debug, Installation is finished when 
    the machine is operating normally.

Warning: 1 HEPA filter cannot be washed.
                  2

)

The Pre-filter must be dried before installing into the machine.

)

Pre-filter cleaning steps:

Turn off the machine first, click the "door" at the top, the door will pop up and 

    open, and then you can take out the HEPA filter and the Pre-filter; The HEPA 
    filter must be taken out firstly, and then remove the Pre-filter.
2. Put the Pre-filter into clean water and dry it, then install the HEPA filter and 
    the Pre-filter (note the direction of HEPA filter placement), please install the 
    pre-filter firstly then HEPA filter.

3. Close the "door".

1. 

Note: When the filter replacement indicator on the operation panel is on, it
           means that the filter needs to be replaced.

Summary of Contents for TDX200-BG02

Page 1: ...LL MOUNTED VENTILATOR TDX200 BG02 User Manual Add 59th LinSheng Road Tinglin Town JinShan District Shanghai China Tel 400 187 8599 Website www thenowair com Shanghai Thenow Purification Technology Co Ltd ...

Page 2: ... Product Structure Operation Panel Product Instructions Installation Guidelines Maintenance Safety Message Conventions SimpleTroubleshooting Technical Data Packing List 03 03 04 05 06 06 07 07 08 09 Health From THENOW ...

Page 3: ... Reset 5 Power Indicator 6 Speed Indicator L M H from top to bottom 7 Filter Replacement Indicator 1 Control Panel 2 Ventilator Unit 3 LOGO 4 Filter Mounting Port 5 Fresh Air Duct Individually Packed LED Indication Description 1 Power Indicator LED light is turned on while the power switch on When the power switch off the LED light is off 2 Air Speed Indicator In the power on state the correspondi...

Page 4: ... power button for 3 seconds to turn on off the electric auxiliary heating function The default is off Warning The following installation must be performed by professionals 1 First drill a large through hole Ø130MM and four expansion screw holes Ø6mm in the designated position on the wall 2 According to the thickness of the wall adjust the total length of the fresh air duct insert the fresh air duc...

Page 5: ... its distributor to change 7 Do not place objects in the air inlet and outlet and do not block the air inlet and outlet 8 This product is prohibited from water 9 Do not get close to the fire source and do not let thesparks generated by combustible gas or cigarettes and other objects sucked into the unit 10 If the product will not be used for a long time please turn off the power and unplug the pow...

Page 6: ...Cord 3 Wall Bracket 4 User Manual 5 Product Certificate 6 Warranty Card 1pc 1pc 1pc 1pc 1pc 1pc Packing List The pictures on this manual and the outer packaging are for reference only and the boxed products are the actual products ...