Hardware Manual COMBILOG 1020
114
char
meaning
length
range
#
start delimiter for request telegram with
check sum
1 ASCII
"#"
>
start delimiter for response telegram with
check sum
1 ASCII
">"
$
start delimiter for request telegram without
check sum
1 ASCII
"$"
=
start delimiter for response telegram without
check sum
1 ASCII
"="
<cr> end delimiter (carriage return)
1
hex
0D
ACK positive
acknowledge
1
hex
06
NAK negative
acknowledge
1
hex
15
aa
destination address
2
ASCII "01".."7F"
cc
check sum
2
ASCII "00".."FF"
k
channel number
2
ASCII "00".."FF"
v..v device identification
28 ASCII - string
s..s device information
28 ASCII - string
z..z status information
12 ASCII - string
i..i
channel information
32 ASCII - string
d..d channel value
max. 8 ASCII - string
b..b events
variable ASCII - string
e
error code
1
ASCII "1".."2"
t..t
date and time
12 ASCII - string
n..n measuring rate and averaging interval
7
ASCII - string
a..a number of events
5
ASCII - string
p..p password
max. 8 ASCII - string
Table 11.10 Explanation of the command characters in the ASCII-protocol
Summary of Contents for COMBILOG 1020
Page 1: ...COMBILOG 1020 Datalogger Hardware Manual Version 3 09...
Page 2: ...Hardware Manual COMBILOG 1020 2 Issue 03 11 2005 Technical data are subject to change...
Page 4: ...Hardware Manual COMBILOG 1020 4...
Page 6: ...Hardware Manual COMBILOG 1020 6...
Page 12: ...Hardware Manual COMBILOG 1020 12...
Page 86: ...Hardware Manual COMBILOG 1020 86 Bild 8 1 Example Master Slave System...
Page 169: ...Hardware Manual COMBILOG 1020 169...
Page 170: ...Hardware Manual COMBILOG 1020 170...