Hardware Manual COMBILOG 1020
116
If the bit Mn in the module status is set it indicates that an error
has occurred in the datalogger. Valid is:
M1 = 1: EEPROM error
M5 = 1: RTC error
M2 = 1: FLASH error
M6
(currently not occupied)
M3 = 1: ADC error
…
M4 = 1: configuration error
M16
(currently not occupied)
channel information (i...i)
length = 32 char
<channel type>..........................ASCII ................................ 1 char
<channel notation>....................ASCII .............................. 20 char
<data format> ............................ASCII ................................ 1 char
<field length>.............................ASCII ................................ 1 char
<decimals> ................................ASCII ................................ 1 char
<unit> ........................................ASCII ................................ 6 char
<channel configuration> ............ASCII ................................ 1 char
<type of calculation> .................ASCII ................................ 1 char
Coding <channel type>:
ASCII "0" Empty Channel (EM)
ASCII "1" Analog Input Channel (AI)
ASCII "2" Arithmetic Channel (AR)
ASCII "3" Digital Output Channel (DO)
ASCII "4" Digital Input Channel (DI)
ASCII "5" Setpoint Channel (VO)
ASCII "6" Alarm Channel (AL)
Coding <channel configuration>:
Bit 1:
tare/reset possible
Bit 2:
average value storage configured
Summary of Contents for COMBILOG 1020
Page 1: ...COMBILOG 1020 Datalogger Hardware Manual Version 3 09...
Page 2: ...Hardware Manual COMBILOG 1020 2 Issue 03 11 2005 Technical data are subject to change...
Page 4: ...Hardware Manual COMBILOG 1020 4...
Page 6: ...Hardware Manual COMBILOG 1020 6...
Page 12: ...Hardware Manual COMBILOG 1020 12...
Page 86: ...Hardware Manual COMBILOG 1020 86 Bild 8 1 Example Master Slave System...
Page 169: ...Hardware Manual COMBILOG 1020 169...
Page 170: ...Hardware Manual COMBILOG 1020 170...