Hardware Manual COMBILOG 1020
82
Note:
The datalogger can write data to pre-formatted memory
cards only. The following file systems are supported:
-
Microsoft Flash File System
-
TrueFFS
®
-FTL (MSystems)
To read the cards on a PC a driver for the respective file system
must be installed. At present only 16 bit drivers are available for
the file systems above, so it can not be used for Windows
NT/2000.
Theodor Friedrichs & Co. delivers pre-formatted flash memory
cards, that can directly used for the Combilog.
Structure of the data file COMBILOG.LOG:
Identification COM1020
M2.10U3.00
Location COMBILOG
Serial No
123456
Sample Rate
1
Store Rate
3600
Code Time
Variable
1
Variable
2
... Variable
n
0 01.11.99
08:00:00
3.45
1.28
...
3.44
0 01.11.99
08:00:00
3.45
1.28
...
3.44
0 01.11.99
08:00:00
3.45
1.28
...
3.44
0 01.11.99
08:00:00
3.45
1.28
...
3.44
Structure of a record:
K T Time T M1 T M2 T … T Mx T S1 T S2 T … Sx CR LF
K
Sign “0” for data record
T
Separation mark (Tabulator or “;“)
Time
Date and time of the data record
(DD.MM.YY HH:MM:SS)
M1
First measured value
M2
Second measured value
Mx
Last measured value
S1
First external channel
Summary of Contents for COMBILOG 1020
Page 1: ...COMBILOG 1020 Datalogger Hardware Manual Version 3 09...
Page 2: ...Hardware Manual COMBILOG 1020 2 Issue 03 11 2005 Technical data are subject to change...
Page 4: ...Hardware Manual COMBILOG 1020 4...
Page 6: ...Hardware Manual COMBILOG 1020 6...
Page 12: ...Hardware Manual COMBILOG 1020 12...
Page 86: ...Hardware Manual COMBILOG 1020 86 Bild 8 1 Example Master Slave System...
Page 169: ...Hardware Manual COMBILOG 1020 169...
Page 170: ...Hardware Manual COMBILOG 1020 170...