Item  

Part No. 

Qty. 

Description

 

 

40288 

 

Accumulator 

4022636 

 

Air Filter, Pleated, 2” x 20” x 20”

 

402264 

 

Air Filter, Pleated, 4” x 20” x 20”  

 

 

 

MERV-8

  

4022624 

 

Air Filter, Pleated, 4” x 20” x 20”  

 

 

 

(90-95% EFFICIENT)

402083 

 

Blower w/ Capacitor

4022622 

Bumper, Foot, .50 Dia. x .75 High

407777 

Capillary Tubes, .059” ID x .24”  

 

 

 

OD x 32” long

4022563 

 

Coil, Condenser

4022557 

 

Coil, Evaporator

4022600 

 

Compressor, Carlyle  

 

 

 

(P/N EBA35A)(HP Model)

 

4023645 

 

Compressor Kit, Carlyle  

 

 

 

(P/N EBA20A) (4022750  

 

 

 

Compressor only)

4022595 

 

Compressor Overload, Carlyle  

 

 

 

(included with compressor)

4022634 

 

Condensate Pump 

 

402265 

 

Cord and Wire Harness

402908 

 

Drain Hose  

 

 

 

(.38 ID x .56 OD x 33’ long)

40226 

 

Outlet Collar (for Ducting Outlet)

4022593 

 

Filter/Drier (not shown)

402597 

 

Hour Meter

402089 

 

Indicator Light, Red, 25V

402266 

 

Instruction Label (not shown)

402229 

 

Low Pressure Control

97000 

 

Relay

20 

4022740 

 

Run Capacitor, 30 MFD, 370V

402997 

Spring

22 

402796 

 

Switch, Pump Purge

23 

402822 

 

Switch, Power

24 

402470 

 

Thermostat, Defrost

 

402648 

 

Thermostat, Defrost,  

 

 

 

Mounting Clip

25 

402823 

 

Timer, Defrost

26 

4022878 

 

Time Delay (HP Model)

27 

402263 

Wheel, 2”, Plastic 

20

15

12

1

13

23

24

25

26

11

4

7

8

17

18

2

19

22

14

16

3

27

10

26

6

9

6 Service Parts

Items listed are not shown

 

4022597 

 

Wiring Diagram (on Cover) 

 

 

 

(not shown) 

 

402950 

 

Ground Fault Interrupter  

 

 

 

(optional) 

 

4023079 

 

Coupling, Body,  

 

 

 

Quick Connect, .38 Tube

 

4023080 

 

Coupling, Insert,  

 

 

 

Quick Connect,.38 Tube

Specifications subject to change without notice.

Summary of Contents for 4022599

Page 1: ...s filtration dramatically improves the air quality in the areas being dried and assures continued optimal performance of the refrigeration system The Phoenix 300 High Capacity Dehumidifier High capacity Up to 38 gallons per day High energy efficiency Plugs into a grounded 115V outlet Pleated media filter Built in air filter reduces dust and mold Twist on duct collar Direct the drying power where y...

Page 2: ...st 1 foot from walls and other obstructions to air flow If the humid area is very large dehumidification can be improved by adding an outlet duct to circulate air to stagnant areas see Sec 2 5 Table of Contents Introduction 1 1 Specifications 2 2 Operation 2 2 1 Transporting the Phoenix 300 2 2 2 Location 2 2 3 Electrical Requirements 2 2 4 Condensate Removal 3 2 5 Ducting 3 2 6 Power Switch 3 2 7...

Page 3: ...e hose stops 2 8 Pump Fail Light If the condensate pump fails water draining into the pump reservoir will fill above its normal level A safety float switch will then turn on the pump fail light located next to the pump purge switch and stop the compressor This prevents water from overflowing and wetting the floor The safety switch will not allow the compressor to restart until water has been remov...

Page 4: ...the Phoenix 300 is stored between uses and both pertain to the water trapped in the unit damage caused by freezing and biological growth The effect of the trapped water can be greatly reduced if precautions are taken to remove as much as possible before storage 1 Use the pump purge switch see Sec 2 7 and Fig 3 to reduce the water level in the reservoir 2 Stretch the hose flat to drain it completel...

Page 5: ...c 4 6A 5 Defective compressor Sec 4 6 6 Defective relay Sec 4 9 7 Defective time delay Sec 4 10 No dehumidification Blower runs but compressor does not Pump fail light not lit 1 Bad connection in compressor circuit Fig 3 2 Defective compressor capacitor Sec 4 6A 3 Defective compressor overload Sec 4 6A 4 Defective compressor Sec 4 6 5 Defective relay Sec 4 9 6 Defective time delay Sec 4 10 No dehu...

Page 6: ...e relay terminal that the black wire from the compressor connects to and b the capacitor terminal with the 3 white wires and 1 red wire connected If voltage is present go to step 3 If no voltage the low pressure control the time delay or the relay are open or there is a loose connection in the compressor circuit Test each component for continuity see the appropriate section if a defect is suspecte...

Page 7: ...the system for at least an hour 8 Operate the system for a short period of time monitoring the suction pressure to determine that the suction filter is not becoming plugged Replace the suction filter drier if pressure drop occurs If a severe running burn out has occurred several filter driers may have to be replaced to remove all of the acid and moisture NOTE NEVER use the compressor to evacuate t...

Page 8: ...low pressure control time delay HP model defrost thermostat and timer 4 10 Time Delay HP model only The HP model has a time delay relay in the compressor control circuit This relay delays the compressor start about 2 minutes after the power switch is turned on This reduces the unit s starting amp draw by starting the blower and compressor at different times This reduces the chance of tripping a ci...

Page 9: ...2 4021908 1 Drain Hose 38 ID x 56 OD x 33 long 13 4022611 1 Outlet Collar for Ducting Outlet 14 4022593 1 Filter Drier not shown 15 4021597 1 Hour Meter 16 4021089 1 Indicator Light Red 125V 17 4022616 1 Instruction Label not shown 18 4022219 1 Low Pressure Control 19 1970010 1 Relay 20 4022740 1 Run Capacitor 30 MFD 370V 21 4021997 6 Spring 22 4021796 1 Switch Pump Purge 23 4021822 1 Switch Power...

Page 10: ...10 www thermastor com sales thermastor com Toll Free 1 800 533 7533 This page intentionally left blank ...

Page 11: ...ther reasonable and reliable means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitations and Exclusions If any Phoeni...

Reviews: