background image

6

www.thermastor.com • sales@thermastor.com

Toll-Free 1-800-533-7533

the device’s power cord. Should an over-current condition 
occur, the Axial Air Movers’ on-board circuit breaker 
prevents nuisance visits to a remote power junction box.

IMPORTANT: Total amperage of the Axial Air Mover plus all 
devices plugged into the receptacle must not exceed 12 
amps. The circuit breaker will not allow for loads in excess 
of 12 amps, although there is a time delay before the 
overloaded circuit is broken.

8.3 Power Indication Lamp

The red, sealed, high intensity AC voltage power indication 
lamp allows operators to visually identify the operation 
status of several Phoenix Axial Air Movers at a distance, 
with a single glance. The power indication lamp will remain 
lit when the AC power cord is plugged into a standard 
“powered” AC power outlet and the 3-position drying 
selector switch is in either the HIGH or LOW operation 
position. The power indication lamp will remain unlit when 
the AC power cord is unplugged, the 3-position drying 
selector switch in the OFF position, the on-board GFCI 
or 2 Amp circuit breaker is tripped, or the connected, 
standard AC wall outlet power has been turned off.

8.4 3-Position Drying Selector Switch

The 3-position drying mode selector switch. This switch 
is used to select the Phoenix Axial Air Mover’s mode of 
operation. The 3 modes of operation are OFF, LOW or 
HIGH.

IMPORTANT: When the Phoenix Axial Air Mover is plugged 
into a standard “powered” wall outlet the Phoenix Axial Air 
Mover’s duplex outlets are electrically “HOT” and AC voltage 
is present.

OFF

 

- The Phoenix Axial Air Mover is not drying. The 

power indication lamp is unlit. If the unit is plugged into a 
standard “powered” wall outlet all devices connected to 
the unit’s duplex GFCI outlet receive AC voltage.

LOW 

- The Phoenix Axial Air Mover is in “Normal” Drying 

mode. This mode provides rapid drying and very quiet 
operation. The power indication lamp will be lit. All devices 
connected to the devices duplex GFCI outlet will receive AC 
voltage.

HIGH

 - The Phoenix Axial Air Mover is in “Fast” drying 

mode. This mode provides the industries most rapid 
drying while maintaining low noise operation. The power 
indication lamp will be lit. All devices connected to the 
devices duplex GFCI outlet will receive AC voltage. 

8.5 GFCI Protection and the On-Board Duplex 
VAC Outlet

The standard AC voltage outlet GFCI (Ground Fault Circuit 
Interrupter) protection promotes operator safety in wet 
applications. GFCI devices trip when a fault to electrical 
“ground” is sensed. 
It is recommended to check the GFCI protection prior to 
operation. To check, push the “TEST” button located on 
the GFCI duplex outlet. If operating properly the “RESET” 
button on the GFCI outlet will pop out. Depending on your 
Axial Air Movers specific equipment, a tripped GFCI may be 
indicated by a small LED. The device can only be “RESET” 
when the Axial Air Mover is connected to a wall outlet 
providing standard voltage. This duplex AC outlet allows 
the inter-connection of other AC powered devices. The sum 
total amperage of all devices plugged into the receptacle 
must not exceed 9 amps.

9 Maintenance

WARNING: Disconnect the unit from power before servicing,  
lubrication or cleaning. Replace the wire safety grill after  
servicing, lubrication or cleaning. 

9.1 Servicing

Before each use inspect for damage, blocked inlet or 
outlet, or any excess buildup of foreign material.
Inspect the GFCI to ensure it is not in a “tripped” 
condition. Push “RESET” to reset the GFCI.
When the Phoenix Axial Air Mover is first turned on, check 
for excessive vibration. If the unit vibrates excessively or if 
blade rubs on housing, turn off the unit immediately. Have 
a service technician inspect the unit to locate the problem.

Figure 10: Oil hole 
locations. Access the 
oil holes by removing
the protective grill(s) 
and turning the unit 
upside down.

Summary of Contents for Phoenix TS-285

Page 1: ...al air movers create a circular air jet With a circular air jet the only way to get air into the square corner is to point the fan towards the corner This angle toward the wall wastes valuable air velocity and throw distance FOCUSTM Technology creates an air jet with a square corner resulting in optimized drying ability In addition the Axial Air Mover features built in 4 5 positioning which increa...

Page 2: ...toyage Ne pas utiliser l appareil avec un cordon d alimentation coupé ou effiloché Ne pas débrancher l appareil en tirant sur le cordon Tenir la fiche fermement et la tirer hors de la prise murale ou la prise d alimentation électrique Toujours utiliser une prise mise à la terre Ne jamais utiliser l équipement électrique dans de l eau stagnante Ne jamais utiliser sans les grilles de protection Des ...

Page 3: ...SA STD C22 2 No 113 4 Specifications Part No 4025200 Power 1 4 hp 1 phase 110 120 VAC 2 speed 4 pole PSC Electric Motor CFM Approximately 3000 Cord 20 ft Power Cord Outlet 15A UL Rated GFCI Duplex Receptacle Current Draw 2 5 Amps Voltage 115 VAC Warranty Year One 100 parts and labor all components Year Two 100 parts only all components Years Three through Seven Only materials and workmanship of th...

Page 4: ... ease of use The axial air mover ships with rubber feet on one side of the unit for counter clockwise drying When the water restoration professional needs to employ clockwise drying such as the need to dry a door jamb simply rotate the axial air mover 90 so the FOCUS Technology corner points toward the door jamb and floor for the clockwise drying Figure 6 Placement for counter clockwise drying Fig...

Page 5: ...l Air Mover consumes 2 5 Amps Do not plug devices requiring more than 9 0 Amps of current into the duplex outlet 8 Operator Panel Features 8 1 Run Time Hour Meter The operator interface panel is equipped with an Automatic LCD Liquid Crystal Display Hour meter This hour meter displays cumulative run time The hour meter meets IP65 for moisture and dust protection and is designed to survive harsh res...

Page 6: ...in Normal Drying mode This mode provides rapid drying and very quiet operation The power indication lamp will be lit All devices connected to the devices duplex GFCI outlet will receive AC voltage HIGH The Phoenix Axial Air Mover is in Fast drying mode This mode provides the industries most rapid drying while maintaining low noise operation The power indication lamp will be lit All devices connect...

Page 7: ... gets wet during cleaning simply allow ample time for motor to dry out completely before restarting If you clean your device frequently perform motor lubrication more frequently as well If you wash the Axial Air Mover and do not plan to use it within 24 hours allow the fan to drip dry for 10 minutes and then let run for 5 minutes Before storing it apply oil as described above 10 Replacement Parts ...

Page 8: ... www thermastor com sales thermastor com Toll Free 1 800 533 7533 This page intentionally left blank ...

Page 9: ...ation unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any Phoenix Axial Air Mover part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be extended by the period of time if any that the Phoenix Axial Air Mover with FOCUS Technology is o...

Reviews: