background image

8

www.thermastor.com • sales@thermastor.com

Toll-Free 1-800-533-7533

This page intentionally left blank.

Summary of Contents for Phoenix TS-285

Page 1: ...al air movers create a circular air jet With a circular air jet the only way to get air into the square corner is to point the fan towards the corner This angle toward the wall wastes valuable air velocity and throw distance FOCUSTM Technology creates an air jet with a square corner resulting in optimized drying ability In addition the Axial Air Mover features built in 4 5 positioning which increa...

Page 2: ...toyage Ne pas utiliser l appareil avec un cordon d alimentation coupé ou effiloché Ne pas débrancher l appareil en tirant sur le cordon Tenir la fiche fermement et la tirer hors de la prise murale ou la prise d alimentation électrique Toujours utiliser une prise mise à la terre Ne jamais utiliser l équipement électrique dans de l eau stagnante Ne jamais utiliser sans les grilles de protection Des ...

Page 3: ...SA STD C22 2 No 113 4 Specifications Part No 4025200 Power 1 4 hp 1 phase 110 120 VAC 2 speed 4 pole PSC Electric Motor CFM Approximately 3000 Cord 20 ft Power Cord Outlet 15A UL Rated GFCI Duplex Receptacle Current Draw 2 5 Amps Voltage 115 VAC Warranty Year One 100 parts and labor all components Year Two 100 parts only all components Years Three through Seven Only materials and workmanship of th...

Page 4: ... ease of use The axial air mover ships with rubber feet on one side of the unit for counter clockwise drying When the water restoration professional needs to employ clockwise drying such as the need to dry a door jamb simply rotate the axial air mover 90 so the FOCUS Technology corner points toward the door jamb and floor for the clockwise drying Figure 6 Placement for counter clockwise drying Fig...

Page 5: ...l Air Mover consumes 2 5 Amps Do not plug devices requiring more than 9 0 Amps of current into the duplex outlet 8 Operator Panel Features 8 1 Run Time Hour Meter The operator interface panel is equipped with an Automatic LCD Liquid Crystal Display Hour meter This hour meter displays cumulative run time The hour meter meets IP65 for moisture and dust protection and is designed to survive harsh res...

Page 6: ...in Normal Drying mode This mode provides rapid drying and very quiet operation The power indication lamp will be lit All devices connected to the devices duplex GFCI outlet will receive AC voltage HIGH The Phoenix Axial Air Mover is in Fast drying mode This mode provides the industries most rapid drying while maintaining low noise operation The power indication lamp will be lit All devices connect...

Page 7: ... gets wet during cleaning simply allow ample time for motor to dry out completely before restarting If you clean your device frequently perform motor lubrication more frequently as well If you wash the Axial Air Mover and do not plan to use it within 24 hours allow the fan to drip dry for 10 minutes and then let run for 5 minutes Before storing it apply oil as described above 10 Replacement Parts ...

Page 8: ... www thermastor com sales thermastor com Toll Free 1 800 533 7533 This page intentionally left blank ...

Page 9: ...ation unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any Phoenix Axial Air Mover part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be extended by the period of time if any that the Phoenix Axial Air Mover with FOCUS Technology is o...

Reviews: