Info@QuestHydro.com
Quest Dry 180 Condensate Pump Installation
Optional Accessory:
Condensate Pump Kit
P/N 4025845
CAUTION!
Before installing pump kit, disconnect dehumidifier from
electrical power and disconnect drain hose if previously installed.
Condensate Pump Bracket
Tools Required:
5/16" Hex driver
Pump Kit
Part No. 4025845
Parts Included:
OVER
Condensate Pump
assembled to bracket
3
/
8
" x 20 ft hose
Tools Required: Phillips Screwdriver
Note: The (2) white wires located at the top of the condensate pump are overflow safety trip wires (optional). These
wires are not live or hot wires until connected to the dehumidifier or another automatic cut off device. Only a certi-
fied electrician is qualified to connect the safety trip wires to your Therma-Stor dehumidifier. Attaching the overflow
safety trip wires to your Therma-Stor dehumidifier will cut power to the dehumidifier if the pump motor should fail
and the secondary float switch trips (this process is optional and not necessary on every install). You may also use
other low voltage (24 volt) cut off devices that do not involve an electrician. Please contact Therma-Stor if you have
any additional questions.
Note: Before attaching pump assembly, ensure that the dehumidifier has leveling feet installed on the bottom of the
unit.
Step 1.
Make sure leveling feet are installed.
Step 2.
Remove middle top cover screw located on
the drain port side. Do not discard this screw. It will be
used to attach the mounting bracket in the next step.