Installation, Operation and Maintenance Instructions  

13

www.QuestProtect.com

sales@QuestProtect.com

6 Service Parts

Item 

Description 

Qty  Part No.

Top Cover 

1   4028583

Top Cover Hinge 

2   4027267

Wheel 12” Gray 

2   4026304

Cotter Pin 3/32” 

2   1284404

Air Filter 1.75 x 15.5 x 19.5 

1   4021475

Hose Vinyl 0.56 ID x 24 

1   4029894

Hose Vinyl 0.38 ID 

1   4021909

Hose Vinyl 0.25ID x 33 

1   4024916

Coupling Body 0.25 Tube 

1   4024910

10 

Coupling Insert 0.38 Tube 

1   4023080

11 

Control Board 

1   4033674

12 

Capacitor Compressor

 

55mfd 370V

  1   4029606

13 

Capacitor Impeller

 15mfd 371V

 

1   4033031-07

14 

Thermistor 

1   4032644

15 

Cord 

1   4032315

16 

Compressor 

11.9KBTU R410a

 

1   4029186

17 

Overload Compressor 

1   4029177

18 

Evaporator Coil 

1   4028565

Item 

Description 

Qty 

Part No.

19 

Condenser Coil 

4028566

20 

Condensate Pump 

4023649

21 

Fan Motorized Impeller 

4026657

22 

Inlet Ring 

4028564

23 

Wire Duct Collar 

4028593

24 

Relay SPST 100/120V 25A 

1970010

25 

Filter Drier (not shown) 

4029510

26 

Wire Harness (not shown) 

4031121

27 

Handle 

4026094

28 

Bolt M10-1.5 X 35 

1177792

29 

Washer M10 X 30 

4025517

30 

Hex Lock Nut M10-1.5 

1223780

31 

Humidity Controller 

4027172

32 

Knob 

4021495

1, 5, 8

7, 9, 10

3, 4

19

18

15

2

24

23

21, 22

16, 17

14

6

20

11

 

27, 28
29, 30

12

13

31, 32

Figure 4

Summary of Contents for Quest PowerDry 4000 Pro

Page 1: ...53704 Toll Free 1 866 933 7486 www QuestProtect com sales QuestProtect com Read and Save These Instructions TS 760 11 14 quest quest 1 Quest PowerDry 4000 Pro High capacity 176 pints day AHAM 22 Gall...

Page 2: ...nsate Removal 5 2 5 Ducting 5 2 6 POWER Button 5 2 7 PURGE Button 5 2 8 Humidistat 6 2 9 HOURS Button 6 2 10 DEFROST Light 6 2 11 Defrost Cycle 6 2 12 Low Pressure Control 6 3 Maintenance 7 3 1 Air Fi...

Page 3: ...s for maintenance and service DO NOT INSTALL UNIT WITH THE SERVICE PANELS INACCESSIBLE Avoid directing the discharge air at people or over the water in pool areas If used near a pool or spa be certain...

Page 4: ...d refrigeration system Dimensions Width 20 Depth 23 Height 40 Weight 135 lbs 2 Operation Place dehumidifier inside structure place condensate hose into a drain or a very large container and turn on To...

Page 5: ...mped more than 20 feet above the unit a second pump must be added to relay the condensate 2 5 Ducting A detachable rectangular exhaust collar is supplied that will allow 10 round lay flat duct to be a...

Page 6: ...w the defrost set point due to excessive frost formation the thermistor activates the solid state control and the defrost light The control cycles the compressor off and on by monitoring thermistor te...

Page 7: ...much as possible before storage 1 Use the pump purge switch see Sec 2 7 and Fig 4 to reduce the water level in the reservoir 2 Stretch the hose flat to drain it completely If the unit will not be expo...

Page 8: ...s the entire coil from inlet to outlet The mixture of gas and liquid refrigerant enter the accumulator after leaving the evaporator coil The accumulator prevents any liquid refrigerant from reaching t...

Page 9: ...control board Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Check to make sure humidistat is set high enough 3 Humidity meter and or thermometer...

Page 10: ...rnal thermal overload protection If defective the complete assembly must be replaced 1 Unplug power cord 2 Remove the front cover 3 Remove the 5 screws attaching blower inlet ring 4 Remove the 4 screw...

Page 11: ...Gravity Drain Option If the condensate pump fails and cannot be replaced immediately the Quest PowerDry 4000 Pro can be used by draining by gravity 1 Unplug the unit and remove the front cover 2 Push...

Page 12: ...IED OB T STOR ENGRG DEPT 3 PROOFS TO BE APPROVED BY T STOR ENGRG DEPT 4 COLORS BLACK LINES LETTERS ON WHITE BACKGROUND PART NO SHEET REV TITLE DRAWN BY CHECKED BY SIGNATURES DATE SCALE A 1 OF 1 INCHES...

Page 13: ...ompressor 55mfd 370V 1 4029606 13 Capacitor Impeller 15mfd 371V 1 4033031 07 14 Thermistor 1 4032644 15 Cord 1 4032315 16 Compressor 11 9KBTU R410a 1 4029186 17 Overload Compressor 1 4029177 18 Evapor...

Page 14: ...reliable means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modifica...

Reviews: