Ventilation Timer/Humidity Control Panel

 (P/N 4024125)

  

(Figure 2, p.7) 

4.6D  

 Ventilation Timer and Humidity Control WITH Fresh Air 
AND Motorized Damper 

DEH 3000 Digital Control 

(P/N 4028539; with remote: P/N 4028407)

 

4.6E  

Digital Controller WITH Fresh Air AND Damper 

4.6F  

Digital Controller WITHOUT Fresh Air 

4.1A Humidity/Fan Control Panel WITHOUT Fresh Air 

Ventilation or Damper 

The humidity/fan control panel automatically controls the humidity 
of the living space. The humidity/fan control panel contains an 
adjustable humidity control and a fan switch. The panel has a 
cover that must remain open to the air within the living space for 
accurate humidity sensing. When the fan switch is in the “ON” 
position, air will be continually filtered and circulated throughout 
the home. For humidity control operation refer to section 4.2. 

4.1B Humidity/Fan Control Panel WITH Fresh Air 

Ventilation and WITHOUT Damper 

The humidity/fan control panel automatically controls the humidity 
of the living space. The humidity/fan control panel contains an 
adjustable humidity control and a fan switch. The panel has a 
cover that must remain open to the air within the living space for 
accurate humidity sensing. Outside air is continually introduced 
whenever fan is “ON.” Manual operation of fan filter switch controls 
outside air ventilation. Since the fan operates whenever the Ultra-
Aire XT150H is dehumidifying outside air will also be introduced. 
For humidity control operation refer to section 4.2. 

4.1C Humidity/Fan Control Panel WITH Fresh Air 

Ventilation AND Damper 

In this configuration, a motorized damper has been installed in the 
fresh air duct. When the fan/filter switch is in the “OFF” position, 
the damper is closed. The Ultra-Aire XT150H will then circulate and 
dehumidify air to provide humidity control. 

When the fan/filter switch is in the “ON” position, the motorized 
damper will open and the fan will run, introducing outside air. The 
unit may or may not be dehumidifying in the ventilation mode, 
depending on the humidity control setting. See Section 4.2 for 
humidity control operation. 

4.1D Ventilation Timer and Humidity Control WITH 

Fresh Air AND Motorized Damper 

Refer to sections 4.7 through 4.9C. 

4.1E DEH 3000 Digital Control WITH Fresh Air  

AND Damper 

Refer to Section 5. 

4.1F DEH 3000 Digital Control WITHOUT Fresh Air 

Refer to Section 5. 

4.2 Humidity Control Adjustment 

Set the humidity control to the desired humidity level for the home. 
Turning the knob clockwise results in a drier setting. See the back 

of the control panel cover for set points. 
The dehumidifier will run continuously until 
the relative humidity (RH) is reduced to the 
humidity control dial setting. Setting the 
humidity control to lower RH levels will NOT 
increase the dehumidification rate; the unit 
will simply run longer to reduce the RH to 
the setting. The Ultra-Aire XT150H unit (and 

refrigerant-based dehumidifiers in general) will reduce a warm 
space’s RH to a lower level than that of a cool space. Therefore 
there is no benefit to set the humidity control to excessively 
low levels in cool rooms; doing so will result in long periods of 
ineffective dehumidifier run time. Settings below 45% are not 
recommended. 

4.3 Fan/Filter Switch 

Turning ON the fan/filter switch will 
cause the Ultra-Aire XT150H fan to run 
continuously, whether the Ultra-Aire XT150H 
is dehumidifying or not. This function is 
desirable if the unit is used for air circulation 
and filtration to achieve maximum indoor air 
quality. When the switch is ON; air will be 

constantly filtered through the Ultra-Aire XT150H and circulated 
throughout the house. When the switch is OFF the fan will operate 
only when the humidity control calls for dehumidification or when 
the ventilation timer calls for ventilation. 

4.4 Ventilation Timer 

The ventilation timer controls the fan and the motorized fresh 
air damper. When the ventilation timer is activated, the Ultra-
Aire XT150H will circulate the indoor air, and bring in fresh air 
from outside. The ventilation timer should be set for the required 
ventilation of the residence. The home should be ventilated with 
fresh air as suggested by applicable codes and standards or as 
required by the homeowner. The ventilation timer is an electronic 
timer that displays the current time. This timer has battery backup, 
so it will not require resetting after a power outage. Following 
a prolonged power outage the display of the timer will flash on 
and off indicating a power outage has occurred. The one-minute 
time increments of the ventilation timer allow you to program the 
ventilation of your home to fit your schedule. 

FOR HVAC INSTALLER ONLY

8

Figure 4

Fan/Filter Switch

Figure 3:

Humidity Control  

Adjustment Knob

Humidity/Fan Control Panel  
P/N 4024155

Ventilation Timer & Humidity 
Control Panel • P/N 4024125

Ultra-Aire XT150H Installer’s & Owner’s Manual

Summary of Contents for Ultra-Aire XT150H

Page 1: ...tdoor air may be ducted to the unit via a six inch round duct This provides fresh air to dilute pollutants and maintain high oxygen content in the air The amount of fresh air ventilation can be regula...

Page 2: ...igital Control WITHOUT Fresh Air 9 4 2 Humidity Control Adjustment 8 4 3 Fan Filter Switch 8 4 4 Ventilation Timer 8 4 4A Setting the Time 9 4 4B Ventilation Schedule 9 4 4C Automatic or Manual Mode 9...

Page 3: ...th space to access the back or side panels for maintenance and service DO NOT INSTALL UNIT WITH THE SERVICE PANELS INACCESSIBLE Avoid directing the discharge air at people or over the water in pool ar...

Page 4: ...l vibration and or noise A drain pan MUST be placed under the unit if installed above a living area or above an area where water leakage could cause damage Place the Ultra Aire XT150H on supports that...

Page 5: ...ating system can be used to supply air to the home If the existing supply goes to isolated areas of the home discharge the supply of the Ultra Aire XT150H into the supply of the existing heating syste...

Page 6: ...lter enclosure of the unit The 6 round collar includes a manual damper Adjust the manual damper to provide the desired amount of fresh air for ventilation The amount of fresh air should be based on th...

Page 7: ...edrooms den etc By ducting this way the air inside the structure will circulate through the Ultra Aire XT150H to be filtered and dehumidified Avoid discharging all the air from the dehumidifier in one...

Page 8: ...ir Refer to Section 5 4 2 Humidity Control Adjustment Set the humidity control to the desired humidity level for the home Turning the knob clockwise results in a drier setting See the back of the cont...

Page 9: ...the week for this program You can choose Mon Sun Mon Fri Sat Sun or any single day of the week The days chosen are shown along the top of the display on the ventilation timer Next press the h button...

Page 10: ...e lead from the unit or damage to the transformers will result Do not direct connect the white lead on the unit to the violet lead on the ventilation control or damage to the transformer will result H...

Page 11: ...ty Range Accuracy 10 95 RH 5 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 Size 4 95 L x 1 06 W x 4 19 H Major Operations n Digital control of Relative Humidity Digital Set Point...

Page 12: ...heck and clean the screen on the outdoor fresh air return seasonally The screen may become plugged during the seasons when there are many particles in the outdoor air 7 Service 7 1 Warranty A warranty...

Page 13: ...uch as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle Sec 5 8 4 Air filter dirty Sec 4 1 4 2 5...

Page 14: ...capacitor Plug in and turn on the unit If the compressor fails to start replace the run capacitor 11 If the unit still does not start adding a hard start kit relay capacitor will provide greater start...

Page 15: ...and bring in fresh air from outside The ventilation timer should be set for the required ventilation of the residence The home should be ventilated with fresh air as suggested by applicable codes and...

Page 16: ...Aire XT150H to the blue 5 lead on the control panel If the pump fails this switch opens the compressor control circuit and stops water production before the reservoir overflows The Ultra Aire XT150H...

Page 17: ...FOR HVAC INSTALLER ONLY 17 Pictorial Electrical Diagrams of Ultra Aire XT150H Ultra Aire XT150H Installer s Owner s Manual...

Page 18: ...t No Qty Description 12 4026687 1 45mFd CAPACITOR COMPRESSOR 13 4022487 1 TRANSFORMER 14 4022484 1 RELAY COMPRESSOR 15 4017021 1 15mFd CAPACITOR IMPELLER 16 4026932 1 COLLAR 10 INCH 17 4026947 1 COLLA...

Page 19: ...Electrically Actuated not shown 32 4024153 1 Cover for Items 28 29 not shown 33 4021495 1 Knob Black 25 shaft 34 4024150 1 Instructions Humidity Fan not shown 35 4024122 1 Instructions Ventilation Ti...

Page 20: ...ng door shut Once the door is shut release the door latch Collar Install Remove the 2 round ducts 3 seals and small bag of mounting hardware from inside the rectangle opening Adhere seals onto the bac...

Page 21: ...costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsib...

Page 22: ...any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2007 Therma Stor LLC All rights reserved PO Box 8680 Madison WI 53708 Phone...

Reviews: