EX-TRAFIRE
®
40SD
Operator Manual, Revision T-15
8-57
Fault
This may mean Cause
Solution
The LED3
illuminates�
V
•
Gas pressure
fault�
•
The gas input
pressure is lower
than 3 bar/43 psi�
•
Check gas supply input
pressure�
• Damaged torch
lead�
• Replace the torch lead�
• Pressure switch
fault�
• Incorrect pressure�
• Change the pressure switch
inside the power supply�
The LED3
blinks no arc
output when
the trigger is
depressed�
V
• Consumables
fault�
• Consumables are
loose, improperly
installed or missing�
• Install the consumables and
fit the retaining cap�
• The retaining cap
is not installed or
tightened correctly�
• Fit the retaining cap and
correctly tighten�
• Non original
consumables�
• Use original new
consumables�
• Short circuit
inside the torch�
• Consumables are
incorrectly installed�
• Install the consumables
correctly�
• Dirt inside the
torch�
• Remove all consumables,
clean the inside of the torch�
Reassemble in correct order�
RUN/TEST
switch set to
TEST or press
the torch
trigger but no
gas output�
• Gas valve or
power supply
fault�
• Cable to the gas
valve disconnected�
• Contact your distributor�
• Gas valve
malfunction�
• Contact your distributor�
• Switch or trigger
malfunctioning�
• Contact your distributor�
Summary of Contents for EX-TRAFIRE 40SD
Page 10: ...EX TRAFIRE 40SD Operator Manual Revision T 15 10 Blank page...
Page 65: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 65 Notes...
Page 66: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 66 Notes...
Page 67: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 67 Notes...
Page 68: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 68 Notes...
Page 70: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 70 Revision history...