EX-TRAFIRE
®
40SD
Operator Manual, Revision T-15
8-59
Fault
This may mean Cause
Solution
The pilot arc
is difficult to
ignite and cuts
out�
• Consumables
fault�
• Check for worn
consumables�
• Change the consumable
which may be worn�
• Air pressure fault� • The air pressure is
too high�
• Adjust the air pressure
output�
Output is
restricted and
can not be
controlled�
• Connection
failure�
• Input or output
connection leads�
• Check all input and output
connection cables�
• Fluctuating
connection
between the clamp
and work piece�
• Ensure that the work lead has
a good connection to a clean
and dry area of work piece�
Cut quality
issues�
• Incorrect current
setting�
• Poor quality�
• Adjust the current to suit the
thickness of material to be
cut�
• Consumables
fault�
• Consumables are
worn�
• Inspect consumables –
see section FHT-EX
®
40
Consumable part inspection�
• Incorrect cutting
technique�
• Poor cut quality�
• Adjust the current to suite
the cutting speed and
torch-to-workpiece distance
according to the thickness of
material to be cut�
• Poor connection�
• Work piece is dirty /
contaminated�
• Clean the surface of the work
piece�
For more detailed information see Service Manual
Summary of Contents for EX-TRAFIRE 40SD
Page 10: ...EX TRAFIRE 40SD Operator Manual Revision T 15 10 Blank page...
Page 65: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 65 Notes...
Page 66: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 66 Notes...
Page 67: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 67 Notes...
Page 68: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 68 Notes...
Page 70: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 70 Revision history...