English 14
2.
Place bracket on floor near the center of where the unit
is to be finally located (shown in
Figure 12
).
•
If the range is moved to a new location, the Anti-Tip
Device must be reinstalled.
3.
Secure bracket into the wall stud and to the floor using
the screws provided.
4.
Later, when the unit is installed, the adjustable legs will
allow the cast base to slide under the bracket hook,
stabilizing the unit.
Step 6: Gas Requirements and
Hookup
Verify the type of gas being used at the installation site.
Make certain the range matches the type of gas available
at this location. The appliance is shipped from the factory
for use with natural gas. It must be converted for use with
propane.
Field conversion of the appliance for use with propane gas
supply will require installation of the conversion kit supplied
with the range (service number 553182). A qualified
technician or installer must do the conversion. See LP
Conversion Kit instructions for full installation information.
Obey all instructions in this kit for correct conversion of the
gas regulator and settings for the gas valves.
Figure 13:
Anti-tip Bracket
With the range in its final installed
location, the hook of the anti-tip
bracket will overhang the back of
the range’s cast-aluminum base, in
a position just above the cast base.
Use (2) of the mounting
screws through these two
holes to fasten the anti-tip
bracket to the floor.
Use (2) mounting screws
(or drywall anchors, as
appropriate) through two
of these holes to fasten
the anti-tip bracket to the
rear wall.
CAUTION:
When connecting unit to propane gas, make certain the
propane gas tank is equipped with its own high pressure
regulator in addition to the pressure regulator supplied
with the appliance. The pressure of the gas supplied to
the appliance regulator must not exceed 14" water
column (34.9 mb).
CAUTION:
Do not remove the back cover of the range. It is for an
authorized servicer access only.
WARNING:
If a gas conversion kit is used, the kit shall be installed
by a qualified service agency in accordance with the
manufacturer’s instructions and all applicable codes and
requirements of the authority having jurisdiction. If the
information in the instructions is not followed exactly, a
fire, explosion, or production of carbon monoxide may
result causing property damage, personal injury, or loss
of life. The qualified service agency is responsible for the
proper installation of the kit. The installation is not proper
and complete until the operation of the converted appli-
ance is checked as specified in the manufacturer’s
instructions supplied with the kit.
Summary of Contents for Professional PRO-HARMONY PRD36