background image

1

INSTALLATION INSTRUCTIONS MANUAL

30" BUILT-IN RANGES WITH COOK'N'VENT

 ELECTRIC MODEL RED30V

DUAL-FUEL MODEL RDDS30V

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

IMPORTANT:

Save these instructions for the local electrical inspector’s use.

INSTALLER:

Please leave these Installation Instructions with this unit for the owner.

OWNER:

Please retain these instructions for future reference.

IMPORTANT: LOCAL CODES VARY. INSTALLATION, ELECTRICAL CONNECTIONS

AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES.

Check your local building codes for the proper method of

installation.  In the U.S.A., if there are no applicable local codes,
this unit should be installed in accordance with the National Fuel
Gas Code #Z223.1-Current Issue, and the National Electrical
Code ANSI/NFPA No. 70 Current Issue.  (In Canada, installation
must be in accordance with the CAN 1-B149.1 and .2 - Installation
Codes for Gas Burning Appliances and/ or local codes).

MOBILE home installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
{formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD (Part 280)} or, when such standard is
not applicable, the Standard for Manufactured Home Installations,
ANSI A255.1 / NFPA501A, or with local codes.

Ne pas emmagasiner ou utiliser de l’essence
ou des autres vapeurs inflammables et liquides
aux endroits de celui-ci ou aucun autre
appareil.

 CE QUI FAIRE SI VOUS SENTEZ LE GAZ

Ne pas essayer d’allumer aucun appareil

Ne pas toucher aucun interrupteur
électrique; ne pas utiliser aucun téléphone
dans votre bâtiment.

Appeler immédiatement votre fournisseur
de gaz du téléphone d’un  voisin. Suivre
l’instruction du fournisseur de gaz.

Si vous ne pouvez pas contacter votre
fournisseur, téléphoner le service des
incendies.

L’installation et le service doivent être

exécutés par un installateur qualifié, une agence
de service ou le fournisseur de gaz.

WARNING: If the information in this manual
is not followed exactly, a fire or explosion may
result causing property damage, personal
injury or death.

UL LISTED #157J       FILE # E521958

AVERTISSEMENT:

 Avant l’installation, COUPER au tableau de service, et fermer a clef le tableau de service
pour empecher l’alimination d’etre allumée per hasard.

WARNING:

Before installing turn power OFF at the service panel. Lock service panel to prevent
power from being turned ON accidentally.

AVERTISSEMENT: Si l'information dans ce
manuel n'est pas suivie exactement, un feu ou
une explosion peut résulter et causer des dégâts
matèriels et des risques d'accidents, ou la mort.

Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

 •

Do not try to light any appliance.

 •

Do not touch any electrical switch; do not
use any phone in your building.

 •

Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.

 •

If you cannot reach your gas supplier, call
the fire department.

Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.

Summary of Contents for RDDS30V

Page 1: ...GAZ Ne pas essayer d allumer aucun appareil Ne pas toucher aucun interrupteur lectrique ne pas utiliser aucun t l phone dans votre b timent Appeler imm diatement votre fournisseur de gaz du t l phone...

Page 2: ...tion appropri e des gaz par le conduit de fum e chemin e des appaeils combustible pour viter le refoulement Suivre la directive des fabricants du mat riel chauffant et les normes de s curit tel que ce...

Page 3: ...rface and the bottom of an unprotected wood or metal cabinet or 24 inches when bottom of wood or metal cabinet is protected by not less than 1 4 of flame retardant material covered with not less than...

Page 4: ...ve the existing back brace see Figure 27 Page 18 and use floor mounted anti tip bracket see Figure 30 Page 19 NOTE Follow all measurements precisely If working with nonstandard cabinets take care to a...

Page 5: ...au de 14 0 pounces du r gulateur du r servoir de gaz du propane WARNING Do not attempt any adjustment of the pressure regulator except conversion to propane AVERTISSEMENT Ne pas entreprener aucun ajus...

Page 6: ...If local code requires separate ground separate white wire and bare gound wire connect white to white and ground bare wire separately GAS CONNECTION MODEL RDDS30V GAS CONNECTION For gas units a 1 2 N...

Page 7: ...wer Cord Receptacle Integral Blower Front Rail 2 Units using Remote Blower a Wiring the Remote Blower Wire connections between the range and remote blower shall be made as follows 1 Remove plenum cove...

Page 8: ...ust to roof angle Tape all joints to prevent air leaks NOTE The unit must be sealed between the roof or wall and the underside of the flange with roofing mastic to prevent leaks For installation on a...

Page 9: ...ng See pages 10 to 12 for specific installation steps Threaded rods included in the blower kit will be secured to the mounting nuts A or B shown in Figure 15 Further installation instructions are spec...

Page 10: ...nsure gasket between blower and plenum is compressed 1 Determine blower direction and cutout in cabinet as shown in Figs 16 17 Remove the existing 1 4 20 screws from either positions A or B and discar...

Page 11: ...plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting bracket over rear mounting rod lower nut 6 Rotate blower mounting bracket under blower...

Page 12: ...rod has one preset nut which shall be tightened against plenum 4 Place blower inlet over plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting...

Page 13: ...to standard ducts See Figure 21 Exterior ducting may be routed right left rear up rear wall above and below floor line See Figure 22 VENTILATION Figure 21 Ducting Adapters Model RD7 Model RD310 REMOT...

Page 14: ...will need to transition from other duct sizes to achieve the 10 diameter Be sure to use proper transitions from one size duct to another NOTE You need to calculate the equivalent lengths of straight d...

Page 15: ...420 C F M BLOWER DUCT SIZING Based on the blower position determine the required straight duct length and size and the number and types of elbows or transitions Calculate the total equivalent length u...

Page 16: ...16 BLOWER DUCT SIZING...

Page 17: ...Cap Round to 3 1 4 x 10 Round to 3 1 4 x 10 90 Elbow 45 Elbow 3 1 4 x 10 to 10 Dia Model 310TR10 Equiv Length 1 Ft Fitting Straight Dia Length 6 5 Ft 7 4Ft 8 3 Ft Fitting Straight Dia Length 6 1 Ft 7...

Page 18: ...shall allow the range back brace to slide under the anti tip bracket See Figure 26 c If necessary add spacer between bracket and wall to insure anti tip bracket engagement d Slide range into position...

Page 19: ...LATION Figure 29 Placement of Anti tip Bracket to Floor TopView 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 1234...

Page 20: ...dor reserves the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the United Sta...