Installation and connection
en-us
7
Before using for the first time
1.
Remove leaflets, adhesive tape and protective
foil.
2.
Clean the appliance.
Water connection
9
CAUTION!
■
Installation and connection of the appliance
must be carried out by qualified technicians
according to the installation instructions
supplied.
■
To avoid damage to the appliance and to
ensure its proper functioning, it should only be
connected to a drinking water system.
■
To avoid water damage, a shut-off valve must
be installed.
Water pressure of drinking water system
9
CAUTION!
To avoid damage to the appliance, a pressure
relief valve must be installed between the
drinking water connection and the tubing,
should the water pressure exceed the
maximum value.
Note:
If the water pressure is too low, this will impair
the relevant functions of the appliance.
■
Min. 0.2 Mpa (2 bar)
■
Max. 0.8 Mpa (8 bar)
Electrical connection
9
CAUTION!
Do not connect the appliance to electronic
energy saver plugs.
Note:
You can connect the appliance to mains-
controlled and sine-controlled inverters.
Mains-controlled inverters are used for photovoltaic
systems which are connected directly to the national
grid. Sine- controlled inverters must be used for
isolated applications. Isolated applications, e.g. on
ships or in mountain lodges, are not directly
connected to the national grid.
1.
After installing the appliance, wait at least 1 hour
before connecting it to prevent damaging the
compressor.
2.
Connect the appliance via a correctly installed
outlet.
9
WARNING
RISK OF ELECTRIC SHOCK!
The appliance must be properly grounded.
Never cut through or remove the third
(ground) conductor of the power cord.
Never use adapters.
Never use extension leads.
Requirements for outlets
Maximum simultaneous load
3.
Connect the appliance to a socket near the
appliance.
The socket must be freely accessible even after
the appliance has been installed.
Outlet with
115 V
protective
conductor
60 Hz
Fuse
10 A ... 16 A
Freezer 18"
3.5 A
Freezer 24"
4.0 A
Freezer 30"
4.5 A