4.
Technical Specifications
Europa 640
Europa 380
Pixel Resolution
640 x 512
384 x 288
Accuracy
Standard/Industrial: ± 3 °C (± 5.4 °F) or ± 3%
Medical: ± 1 °C (± 1.8 °F) or ± 1%
Temperature Range
Standard/ Industrial: -20 °C to 150 °C (-4 °F to 302 °F)/
0 °C to 500 °C (32 °F to 932 °F)
Medical: 0 °C to 60 °C (32 °F to 140 °F)
Operation Range
-40 °C to 80 °C (-40 °F to 176 °F)
Storage Range
-45 °C to 85 °C (-49 °F to 185 °F)
Detector Type
Uncooled VOx microbolometer
Pixel Pitch
12 μm
Spectral Band
8 μm to 14 μm
Lens
see Lens Options
Thermal Sensitivity (NETD)
< (50 mK) 0.05 °C at 25 °C (77°F)
Frame Rate
30 Hz (PAL) or 50 Hz (NTSC)
1
Dimensions (without lens)
26 mm x 26 mm x 22 mm (L x W x D ± 0.5 mm)
(1.02” x 1.02” x
0�87
” (L x W x H ± 0.02”))
2
Power
4V ~ 6V DC, < 1.3W
3
4V ~ 6V DC, < 1.0W
3
Power Protection
Over-voltage; Under-voltage; Reverse Connection
Weight (without lens)
< 21 g (0.75 oz) ± 3 g (0.11 oz)
Zoom
1.0X ~ 8.0X continuous zoom
5
Interface
RS-232; UART (3.3 V)
Expansion Board
Available
Video
Analog: 1 channel PAL or NTSC
1
Digital: BT.656; 8-bit or 14-bit LVCMOS; LVDS
4
Video Mirror
Horizontal; Vertical; Diagonal
5
Image Polarity
White hot or black hot
Image Processing
Digital filter; Imaging denoising
5
Emissivity Correction
0.01 to 1.0
Recticle
R
eveal; Hidden; Shift
5
Humidity
5% to 95% non-condensing
Pixel Operability
> 99 %
Shock
80 G
Vibration
6 G