1
Foreword
The central chiller consists of a refrigeration circuit to
provide cooling of water or coolant.
This manual is to serve as a guide for installing,
operating, and maintaining the equipment. Improper
installation, operation, and maintenance can lead to
poor performance and/or equipment damage. Use
qualified installers and service technicians for all
installation and maintenance of this equipment.
This manual is for our standard product and is
general in nature. Equipment-specific drawings and
supplemental documents are included as needed.
Additional copies of documents are available upon
request.
Due to the ever-changing nature of applicable
codes, ordinances, and other local laws pertaining to
the use and operation of this equipment, we do not
reference them in this manual.
The equipment uses a hydrofluoroolefin (HFO), trade
named R513A, as a chemical refrigerant for heat
transfer purposes. This chemical is sealed and tested
in a pressurized system containing ASME coded
vessels; however, a system failure will release it.
Refrigerant gas can cause toxic fumes if exposed to
fire. Place the equipment in a well-ventilated area,
especially if open flames are present. Failure to
follow these instructions could result in a hazardous
condition. We recommend the use of a refrigerant
management program to document the type and
quantity of refrigerant in the equipment. In addition,
we recommend only licensed and EPA certified
service technicians work on our refrigeration circuits.
Safety Guidelines
Observe all safety precautions during installation,
start-up, and service of this equipment. The
following is a list of symbols used in this manual and
their meaning.
General Warning
Electricity Warning
Sharp Element Warning
Hot Surface Warning
Flammable Material Warning
Explosive Material Warning
General Mandatory Action
Wear Eye Protection
Wear Protective Gloves
Wear Ear Protection
Disconnect Before Carrying Out Maintenance or
Repair
Connect an Earth Terminal to Ground
Only qualified personnel should install, start-up, and
service this equipment. When working on this
equipment, observe precautions in this manual as
well as tags, stickers, and labels on the equipment.
WARNING: Any use or misuse of this equipment
outside of the design intent may cause injury or harm.
WARNING: Vent all refrigerant relief valves in
accordance to ANSI/ASHRAE Standard 15, Safety Code
for Mechanical Refrigeration. Locate this equipment in
a well-ventilated area. Inhalation of refrigerant can be
hazardous to your health and the accumulation of
refrigerant within an enclosed space can displace
oxygen and cause suffocation.
WARNING: This equipment contains hazardous
voltages that can cause severe injury or death.