5.05 Basic Troubleshooting Guide
WARNING
There are extremely dangerous voltage and power levels present inside this unit. Do not
attempt to diagnose or repair unless you have had training in power electronics measure-
ment and troubleshooting techniques.
Problem - Symptom Possible Cause
Recommended Action
ON / OFF Switch
is
ON
but the A/C
Indicator does not
light
1. Primary power disconnect is in
OFF position.
2. Primary fuses / breakers are
blown or tripped.
3. Faulty components in unit.
1. Turn primary power disconnect switch to ON position.
2. a) Have qualified person check primary fuses / breakers.
b) Connect unit to known good primary power receptacle
3. Return to authorized service center for repair or replacement.
Fault indicator
flashing, Error Code
E002
1. Primary input voltage problem.
2. Faulty components in unit.
1. Have qualified person check primary voltage to insure it
meets unit requirements see Section "2.05 Input Wiring
Specifications" on page 2-3.
2. Return to authorized service center for repair or replacement.
TEMPERATURE
indicator
ON
.
FAULT indicator
flashing. Error Code
E001
1. Air flow through or around the
unit is obstructed.
2. Duty cycle of the unit has been
exceeded.
3. Failed components in unit.
1. Refer to clearance information – see Section "2.04 Power
Supply Specifications" on page 2-2
2. Allow unit to cool.
3. Return to authorized service center for repair or replacement.
GAS LED
OFF
,
FAULT and MIN
pressure indicators
flashing. Error Code
E016
1. Gas supply not connected to
unit.
2. Gas supply not turned
ON
.
3. Gas supply pressure too low.
4. Failed components in unit.
1. Connect gas supply to unit.
2. Turn gas supply
ON
.
3. Set air supply inlet pressure to unit to 120 psi.
4. Return to authorized service center for repair or replacement.
FAULT and indicators
flashing. Error Code
E004
1. Shield Cup loose.
2. Torch not properly connected to
power supply.
3. Problem in torch and leads PIP
circuit.
4. Failed components in unit.
1. Hand tighten the shield cup until it is snug.
2. Insure torch ATC is securely fastened to unit.
3. Replace torch and leads or return to authorized service center
for repair or replacement.
4. Return to authorized service center for repair or replacement.
FAULT and indicators
flashing. Error Code
E014
1. Start signal is active when ON/
OFF SWITCH is turned to ON
position.
2. Problem in the torch and leads
switch circuit.
3. Failed components in unit.
1. Start can be active for one of the following:
• Hand torch switch held closed
• Hand pendant switch held closed
• CNC START signal is active low
Release the START signal source
2. Replace torch and leads or return to authorized service center
for repair or replacement.
3. Return to authorized service center for repair or replacement.
Summary of Contents for A40i
Page 6: ...This Page Intentionally Blank...
Page 8: ...This Page Intentionally Blank...
Page 12: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 16: ...A40i A60i WARRANTY INFORMATION Manual 0 5466 W 2 This Page Intentionally Blank...
Page 24: ...A40i A60i INTRODUCTION Manual 0 5466 2T 4 This Page Intentionally Blank...
Page 32: ...A40i A60i INSTALLATION Manual 0 5466 3 8 This Page Intentionally Blank...
Page 34: ...A40i A60i INSTALLATION Manual 0 5466 3T 2 This Page Intentionally Blank...
Page 80: ...A40i A60i OPERATION Manual 0 5466 4T 36 This Page Intentionally Blank...
Page 95: ...A40i A60i Manual 0 5466 PARTS LIST 6 3 This Page Intentionally Blank...
Page 99: ...A40i A60i Manual 0 5466 PARTS LIST 6 7 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13...
Page 110: ...A40i A60i APPENDIX Manual 0 5466 A 10 APPENDIX 8 SYSTEM SCHEMATIC 400V 3PHASE CE Art A 13478...
Page 111: ...A40i A60i Manual 0 5466 APPENDIX A 11 Art A 13478...
Page 112: ...A40i A60i APPENDIX Manual 0 5466 A 12 APPENDIX 9 SYSTEM SCHEMATIC 208 480V 3PHASE Art A 13479...
Page 113: ...A40i A60i Manual 0 5466 APPENDIX A 13 Art A 13479...
Page 115: ...This Page Intentionally Blank...