CUTMASTER 40MM
Manual 0-5084
OPERATION
4-3
A
+
PSI
BAR
MAX
MAX
MIN
MIN
!
1
2
Art# A-07946
MIN
MAX
STANDOFF
CutMaster 40mm Gas Pressure Settings
Leads
Length
SL100
(Hand Torch)
SL100
(Mechanized Torch)
SL 100 SV
(Automation Torch)
Up to 50'
(7.6 m)
75 psi
5.2 bar
75 psi
5.2 bar
Each additional
25' (7.6 m)
Add 5 psi
0.4 bar
Add 5 psi
0.4 bar
3. For Drag cutting, adjust gas pressure from 75 -
95 psi / 5.2 - 6.5 bar (LED's in center of control
panel). Refer to the Drag Cutting chart for pres-
sure setting details.
DRAG (60 amps or less)
CutMaster 40mm Gas Pressure Settings
Leads
Length
SL100
(Hand Torch)
Up to 25'
(7.6 m)
80 psi
5.5 bar
Each additional
25' (7.6 m)
Add 5 psi
0.4 bar
Select Current Output Level
1. Place the Function Control Knob in one of the
three operating positions available:
RUN
,
RAPID AUTO RESTART
or LATCH
.
Gas flow stops.
2. Set the output current to desired amperage with
the Output Current Control Knob.
Cutting Operation
When the torch leaves the workpiece during cutting
operations with the Function Control Knob in the
RUN position, there is a brief delay in restarting
the pilot arc. With the knob in the
RAPID AUTO
RESTART
position, when the torch leaves the work-
piece the pilot arc restarts instantly, and the cutting
arc restarts instantly when the pilot arc contacts the
workpiece. (Use the 'Rapid Auto Restart' position
when cutting expanded metal or gratings, or in
gouging or trimming operations when an uninter-
rupted restart is desired). And with the knob in the
LATCH position the main cutting arc will be main-
tained after the torch switch is released.
Typical Cutting Speeds
Cutting speeds vary according to torch output am-
perage, the type of material being cut, and operator
skill. Refer to Section 4T.08 and following for greater
details.
Output current setting or cutting speeds may be
reduced to allow slower cutting when following a
line, or using a template or cutting guide while still
producing cuts of excellent quality.
Postflow
Release the trigger to stop the cutting arc. Gas con-
tinues to flow for approximately 20 seconds. During
post - flow, if the user moves the trigger release to
the rear and presses the trigger, the pilot arc starts.
The main arc transfers to the workpiece if the torch
tip is within transfer distance to the workpiece.
Shutdown
Turn the ON / OFF
switch to OFF
(down).
All Power Supply indicators shut OFF. Unplug the
input power cord or disconnect input power. Power
is removed from the system.
Summary of Contents for CutMaster 40MM
Page 6: ...This Page Intentionally Blank...
Page 24: ...CUTMASTER 40MM INTRODUCTION Manual 0 5084 2T 4 This Page Intentionally Blank...
Page 28: ...CUTMASTER 40MM INSTALLATION Manual 0 5084 3 4 This Page Intentionally Blank...
Page 34: ...CUTMASTER 40MM OPERATION Manual 0 5084 4 4 This Page Intentionally Blank...
Page 43: ...CUTMASTER 40MM Manual 0 5084 OPERATION 4T 9 This Page Intentionally Blank...
Page 56: ...CUTMASTER 40MM OPERATION Manual 0 5084 4T 22 This Page Intentionally Blank...
Page 69: ...CUTMASTER 40MM Manual 0 5084 PARTS LIST 6 3 7 5 6 3 4 2 Art A 07993_AB 1 8...
Page 71: ...CUTMASTER 40MM Manual 0 5084 PARTS LIST 6 5 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13...
Page 74: ...CUTMASTER 40MM PARTS LIST Manual 0 5084 6 8 This Page Intentionally Blank...
Page 79: ...CUTMASTER 40MM Manual 0 5084 APPENDIX A 5 This Page Intentionally Blank...
Page 83: ...This Page Intentionally Blank...