INSTALLATION
Installing Optional Single - Stage Air Filter
An optional filter kit is recommended for im
-
proved filtering with compressed air, to keep
moisture and debris out of the torch.
1. Attach the Single - Stage Filter Hose to the
Inlet Port.
2. Attach the Filter Assembly to the filter
hose.
3. Connect the air line to the Filter. The
illustration shows typical fittings as an
example.
NOTE
For a secure seal, apply thread sealant to the
fitting threads, according to the maker's instruc-
tions. Do Not use Teflon tape as a thread sealer,
as small particles of the tape may break off and
block the small air passages in the torch. Con-
nect as follows:
Art # A-07944
Hose Clamp
1/4 NPT to 1/4"
(6mm) Fitting
Regulator/Filter
Assembly
Inlet Port
Gas Supply
Hose
Optional Single - Stage Filter Installation
Installing Optional Two - Stage Air Filter Kit
This optional two - stage air line filter is also
for use on compressed air shop systems. Filter
removes moisture and contaminants to at least 5
microns.
Connect the air supply as follows:
1. Attach the Two Stage Filter bracket to the
back of the power supply per instructions
supplied with the filter assembly.
NOTE
For a secure seal, apply thread sealant to the fitting
threads according to manufacturer's instructions.
Do Not use Teflon tape as a thread sealer as small
particles of the tape may break off and block the
small air passages in the torch.
2. Connect the two stage filter outlet hose to
the inlet port of the Regulator / Filter As-
sembly.
3. Use customer - supplied fittings to connect
the air line to the Filter. A 1/4 NPT to 1/4"
hose barbed fitting is shown as an example.
Regulator
Input
Gas Supply
Hose
1/4 NPT to 1/4”
(6mm) Fitting
Regulator/Filter
Assembly
2-Stage Filter
Inlet Port (IN)
Outlet Port
(OUT)
Two Stage
Filter
Assembly
Art # A-07945_AC
Optional Two - Stage Filter Installation