CUTMASTER 20mm
SERVICE
5-2
Manual 0-5078
5.02 Maintenance Schedule
NOTE
The actual frequency of maintenance may need
to be adjusted according to the operating envi-
ronment.
Daily Operational Checks or Every Six Cutting
Hours:
1. Check torch consumable parts, replace if damaged
or worn.
2. Check plasma and secondary supply and pres-
sure/flow.
3. Purge plasma gas line to remove any moisture
build-up.
Weekly or Every 30 Cutting Hours:
1. Check fan for proper operation and adequate air
flow.
2. Inspect torch for any cracks or exposed wires,
replace if necessary.
3. Inspect input power cable for damage or exposed
wires, replace if necessary.
Six Months or Every 720 Cutting Hours:
1. Check the in-line air filter(s), clean or replace as
required
2. Check cables and hoses for leaks or cracks, replace
if necessary.
3. Check all contactor points for severe arcing or
pits, replace if necessary.
4. Vacuum dust and dirt
out
of the entire machine.
CAUTION
Do not blow air into the power supply during
cleaning. Blowing air into the unit can cause
metal particles to interfere with sensitive electrical
components and cause damage to the unit.
5.03 Common Faults
Problem - Symptom
Common Cause
Insufficient
Penetration
1. Cutting speed too fast.
2. Torch tilted too much.
3. Metal too thick.
4. Worn torch parts
5. Cutting current too low.
6. Non - Genuine Thermal Dynamics
parts used
7. Incorrect gas pressure
Main Arc
Extinguishes
1. Cutting speed too slow.
2. Torch standoff too high from
workpiece.
3. Cutting current too high.
4. Work cable disconnected.
5. Worn torch parts.
6. Non - Genuine Thermal Dynamics
parts used
Excessive Dross
Formation
1. Cutting speed too slow.
2. Torch standoff too high from
workpiece.
3. Worn torch parts.
4. Improper cutting current.
5. Non - Genuine Thermal Dynamics
parts used
6. Incorrect gas pressure
Short Torch Parts Life1. Oil or moisture in air source.
2. Exceeding system capability
(material too thick).
3. Excessive pilot arc time
4. Gas pressure too low.
5. Improperly assembled torch.
6. Non - Genuine Thermal Dynamics
parts used
Difficult Starting 1. Worn torch parts.
2. Non - Genuine Thermal Dynamics
parts used.
3. Incorrect gas pressure.
ARC WELDING SUPPLIES - 07 847 7870