CUTMASTER 20mm
Manual 0-5078
3T-1
INSTALLATION
SECTION 3 TORCH:
INSTALLATION
3T.01 Torch Connections
If necessary, connect the torch to the Power Sup-
ply. Connect only the Thermal Dynamics model
SL60 / Manual or SL100 / Mechanical Torch to
this power supply. Maximum torch leads length
is 100 feet / 30.5 m, including extensions.
WARNING
Disconnect primary power at the source
before connecting the torch.
1. Align the ATC male connector (on the
torch lead) with the female receptacle.
Push the male connector into the female
receptacle. The connectors should push
together with a small amount of pressure.
2. Secure the connection by turning the lock-
ing nut clockwise until it clicks. DO NOT
use the locking nut to pull the connection
together. Do not use tools to secure the
connection.
1
2
Art # A-07885
Connecting the Torch to the Power Supply
3. The system is ready for operation.
Check Air Quality
To test the quality of air:
1. Put the
ON / OFF
switch in the ON
(up) position.
2. Put the Function Control switch in the SET
position.
3. Place a welding filter lens in front of the
torch and turn on the air.
Do not start an
arc!
Any oil or moisture in the air will be visible
on the lens.
3T.02 Setting Up Mechanical Torch
NOTE
An adapter is required to be installed in the power
supply if converting a hand torch system to oper-
ate a machine torch.
WARNING
Disconnect primary power at the source be-
fore disassembling the torch or torch leads.
The mechanical torch includes a positioning tube
with rack and pinch block assembly.
1. Mount the torch assembly on the cutting
table.
2. To obtain a clean vertical cut, use a square
to align the torch perpendicular to the sur-
face of the workpiece.
ARC WELDING SUPPLIES - 07 847 7870