20
installed on the next adjacent floor
level.
b.
In the event that the requirements of
this subdivision cannot be met at the
time of completion of installation, the
owner shall have a period of (30)
days to comply with the above
requirements; provided, however,
that during said (30) day period, a
battery operated carbon monoxide
detector with an alarm shall be
installed.
2.
APPROVED CARBON MONOXIDE
DETECTORS. Each carbon monoxide
detector, as required in accordance with
the above provisions, shall comply with
NFPA 720 and be ANSI/UL 2034 listed
and IAS certified.
3.
SIGNAGE. A metal or plastic identification
plate shall be permanently mounted to
the exterior of the building at a minimum
height of eight (8) feet above grade
directly in line with the exhaust vent
terminal for the horizontally vented gas
fueled heating appliance or equipment.
The sign shall read, in print size no less
than one-half (1/2) inch in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF
ALL OBSTRUCIONS.”
4.
INSPECTION. The state or local gas
inspector of the side wall horizontally
vented gas fueled equipment shall not
approve the installation unless, upon
inspections, the inspector observes
carbon monoxide detectors and signage
installed in accordance with the
provisions of 248 CMR 5.08(2)(a)1
through 4.
a.
EXEMPTIONS: The following
equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
i.
The equipment listed in chapter
10 entitled “Equipment Not
Required To Be Vented” in the
most current edition of NFPA 54
as adopted by the Board; and
ii.
Product Approved side wall
horizontally vented fueled
equipment installed in a room or
structure separate from the
dwelling, building or structure
used in whole or in part for
residential purposes.
b.
MANUFACTURER REQUIREMENTS-
GAS EQUIPMENT VENTING SYSTEM
PROVIDED. When the manufacturer of
Product Approved side wall
horizontally vented gas equipment
provides a venting system design or
venting system components with the
equipment, the instructions provided
by manufacturer for installation of the
equipment and the venting system
shall include:
i.
Detailed instructions for the
installation of the venting system
design or the venting system
components; and
ii.
A complete parts list for the vent
system design or venting system.
c.
MANUFACTURER REQUIREMENTS-
GAS EQUIPMENT VENTING SYSTEM
NOT PROVIDED. When the
manufacturer of a Product Approved
side wall horizontally vented gas
fueled equipment does not provide
the parts for venting the flue gases,
but identifies “special venting
systems”, the following requirements
shall be satisfied by the manufacturer:
i.
The referenced “special venting
system” instructions shall be
included with the appliance or