9.1 Indoor Unit Error Codes
Display
LED STATUS
E0
Indoor unit EEPROM parameter error
E1
Indoor / outdoor units communication error
E2
Zero-crossing signal detection error
E3
Indoor fan speed has been out of control
E4
Indoor room temperature sensor T1 open circuit or short circuit
E5
Evaporator coil temperature sensor T2 open circuit or short circuit
EC
Refrigerant leakage detection
F0
Overload current protection
F1
Outdoor ambient temperature sensor T4 open circuit or short circuit
F2
Condenser coil temperature sensor T3 open circuit or short circuit
F3
Compressor discharge temperature sensor T5 open circuit or short circuit
F4
Outdoor unit EEPROM parameter error
F5
Outdoor fan speed has been out of control
P0
IPM malfunction or IGBT over-strong current protection
P1
Over voltage or over low voltage protection
P2
High temperature protection of compressor top diagnosis and solution(only for 9k,12k
models)
P3*
Outdoor ambient temperature too low.
P4
Inverter compressor drive error
P5
Indoor units mode conflict (multi-zone ONLY)
*P3
1) In heating mode, when the outdoor temperature is lower than -13°F for 1 hour, the indoor unit display
error code P3.
2) If the OUTDOOR temperature is higher than -8°F for 10 minutes and compressor stop for 1 hour OR
outdoor temperature is higher than -23°F for 10 minutes, then the unit will return to work.
Summary of Contents for 12H47YIMI
Page 10: ...10 1080 mm 226 mm 335 mm 30H48ZIMI 49 57 1259 mm 11 1 282 mm 14 25 362 mm 36H46ZIMI...
Page 19: ...19 Model Voltage V Capacity BTU Type 12H47ZOMI 230 12 000 HEAT PUMP...
Page 56: ...56 P W N U...
Page 57: ...57 N V N W...
Page 82: ...82 7 Then lift the PCB assembly off the unit NOTE All wires are still connected...