Toughpower 1500W
Toughpower 1500W
7. Environments
Operating temperature
Operating humidity
MTBF
0℃
to +40℃
10% to 90%,non-condensing
120,000 hrs minimum
9. Trouble-Shooting
If the power supply fails to function properly, please follow the troubleshooting guide
before application for service:
1.
Is the power cord plugged properly into electrical outlet and into the power supply AC
inlet?
2. Please make sure the “I/O” switch on the power supply is switched to “I” position.
3. Please make sure all power connectors are properly connected to all the devices.
4. Please turn-off and turn-on the power supply with the I/O switch few times with about
0.5 second in the OFF state to reset the PSU.
5. If connected to a UPS unit, is the UPS on and plugged in?
If the power supply is still unable to function properly after following the above
instruction, please contact you
r
local store or Thermaltake branch office for after sales
service. You may also refer to Thermaltake’s website for more technical support:
www.thermaltake.com
Inhaltsverzeichnis
01. Warnungen und Vorsichtshinweis
02. Komponentenüberprüfung
03. Vorstellung der Anschlüsse
04. Installationsschritte
05. Leistungsmerkmale des Produkts
06. Ausgangsspezifikation
08. EMI & SICHERHEIT
07. Betriebsumgebung
09. Problembeseitigung
01
01
01
01
02
03
03
03
03
03
6. Output Specification
DC OUTPUT
Max Output Current
Max Output Power
Continuous Power
Input Voltage: 100V~240V
Input Current: 18A - 9A
Frequency: 60Hz ~ 50Hz
~
AC INPUT
+3.3V
+12V1
+5V
+12V2
40
A
40A
30A
30A
50A
50A
280
W
1320W
1500W
-12V
+5VSB
0.5A
6.0A
6.0W
30W
+12V
3
+12V
4
8. EMI & SAFETY
UL/CUL, CE, FCC, CB+Baurt mark,
GOST and BSMI certified.
TP-1500M Toughpower 1500W
EMI Regulatory & SAFETY Standards